Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid
Само за регистроване кориснике
1991
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
An externally unpolarized twin couple of glassy carbon electrodes, undergoing different pretreatments, and connected to nothing but a recorder, was engaged for simple and fast end‐point detection of electrometric titrations of thioglycollic acid. Microquantities of this substance were determined coulometrically either by its neutralization or by an oxidometric mechanism using the same pair of glassy carbon electrodes in the indicator circuit.
Кључне речи:
glassy carbon electrodes / Cyclic voltammetry / lodometric Titrimetty / Thioglycollic Acid / Coulometry / Alkalimetric DeterminationИзвор:
Electroanalysis, 1991, 3, 3, 227-231Издавач:
- Wiley
Институција/група
IHTMTY - JOUR AU - Jovanović, Vladislava M. AU - Jovanović, Momir S. PY - 1991 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/3666 AB - An externally unpolarized twin couple of glassy carbon electrodes, undergoing different pretreatments, and connected to nothing but a recorder, was engaged for simple and fast end‐point detection of electrometric titrations of thioglycollic acid. Microquantities of this substance were determined coulometrically either by its neutralization or by an oxidometric mechanism using the same pair of glassy carbon electrodes in the indicator circuit. PB - Wiley T2 - Electroanalysis T1 - Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid VL - 3 IS - 3 SP - 227 EP - 231 DO - 10.1002/elan.1140030315 ER -
@article{ author = "Jovanović, Vladislava M. and Jovanović, Momir S.", year = "1991", abstract = "An externally unpolarized twin couple of glassy carbon electrodes, undergoing different pretreatments, and connected to nothing but a recorder, was engaged for simple and fast end‐point detection of electrometric titrations of thioglycollic acid. Microquantities of this substance were determined coulometrically either by its neutralization or by an oxidometric mechanism using the same pair of glassy carbon electrodes in the indicator circuit.", publisher = "Wiley", journal = "Electroanalysis", title = "Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid", volume = "3", number = "3", pages = "227-231", doi = "10.1002/elan.1140030315" }
Jovanović, V. M.,& Jovanović, M. S.. (1991). Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid. in Electroanalysis Wiley., 3(3), 227-231. https://doi.org/10.1002/elan.1140030315
Jovanović VM, Jovanović MS. Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid. in Electroanalysis. 1991;3(3):227-231. doi:10.1002/elan.1140030315 .
Jovanović, Vladislava M., Jovanović, Momir S., "Depolarization end point can glassy carbon electrodes: Microscale coulometry of thioglycollic acid" in Electroanalysis, 3, no. 3 (1991):227-231, https://doi.org/10.1002/elan.1140030315 . .