Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System
Само за регистроване кориснике
2013
Аутори
Minić, DuškoPremović, Milena
Kolarevic, Milan
Ćosović, Vladan
Manasijević, Dragan
Živković, Dragana
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Lead-free solders with copper are considered as a possible substitution for standard lead-tin solders. Ternary Bi-Cu-In system is a potential soldering material based on copper. For a more complete characterization of the ternary Bi-Cu-In system, alloys from the three vertical sections were investigated using microstructural analysis as well as by electrical conductivity and Brinell hardness measurements. The microstructures of the alloys were investigated at room temperature by application of scanning electron microscopy combined with energy dispersive spectrometry and optical microscopy. Isolines of electrical conductivity and hardness for the entire Bi-Cu-In system were calculated using regression models. In addition, a thermodynamic assessment of the system has been carried out by calculation of the isothermal section at 25 A degrees C and description of the liquidus surface using the CALPHAD method. Experimental and analytical results were found to be in a good agreement.
Кључне речи:
Bi-Cu-In system / electrical conductivity / hardness / liquidus / microstructureИзвор:
Journal of Materials Engineering and Performance, 2013, 22, 8, 2343-2350Издавач:
- Springer, New York
Финансирање / пројекти:
- Савремени вишекомпонентни метални системи и наноструктурни материјали са различитим функционалним својствима (RS-MESTD-Basic Research (BR or ON)-172037)
- Развој методологија и средстава за заштиту од буке урбаних средина (RS-MESTD-Technological Development (TD or TR)-37020)
DOI: 10.1007/s11665-013-0493-3
ISSN: 1059-9495
WoS: 000322013000026
Scopus: 2-s2.0-84880921861
Институција/група
IHTMTY - JOUR AU - Minić, Duško AU - Premović, Milena AU - Kolarevic, Milan AU - Ćosović, Vladan AU - Manasijević, Dragan AU - Živković, Dragana PY - 2013 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/1202 AB - Lead-free solders with copper are considered as a possible substitution for standard lead-tin solders. Ternary Bi-Cu-In system is a potential soldering material based on copper. For a more complete characterization of the ternary Bi-Cu-In system, alloys from the three vertical sections were investigated using microstructural analysis as well as by electrical conductivity and Brinell hardness measurements. The microstructures of the alloys were investigated at room temperature by application of scanning electron microscopy combined with energy dispersive spectrometry and optical microscopy. Isolines of electrical conductivity and hardness for the entire Bi-Cu-In system were calculated using regression models. In addition, a thermodynamic assessment of the system has been carried out by calculation of the isothermal section at 25 A degrees C and description of the liquidus surface using the CALPHAD method. Experimental and analytical results were found to be in a good agreement. PB - Springer, New York T2 - Journal of Materials Engineering and Performance T1 - Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System VL - 22 IS - 8 SP - 2343 EP - 2350 DO - 10.1007/s11665-013-0493-3 ER -
@article{ author = "Minić, Duško and Premović, Milena and Kolarevic, Milan and Ćosović, Vladan and Manasijević, Dragan and Živković, Dragana", year = "2013", abstract = "Lead-free solders with copper are considered as a possible substitution for standard lead-tin solders. Ternary Bi-Cu-In system is a potential soldering material based on copper. For a more complete characterization of the ternary Bi-Cu-In system, alloys from the three vertical sections were investigated using microstructural analysis as well as by electrical conductivity and Brinell hardness measurements. The microstructures of the alloys were investigated at room temperature by application of scanning electron microscopy combined with energy dispersive spectrometry and optical microscopy. Isolines of electrical conductivity and hardness for the entire Bi-Cu-In system were calculated using regression models. In addition, a thermodynamic assessment of the system has been carried out by calculation of the isothermal section at 25 A degrees C and description of the liquidus surface using the CALPHAD method. Experimental and analytical results were found to be in a good agreement.", publisher = "Springer, New York", journal = "Journal of Materials Engineering and Performance", title = "Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System", volume = "22", number = "8", pages = "2343-2350", doi = "10.1007/s11665-013-0493-3" }
Minić, D., Premović, M., Kolarevic, M., Ćosović, V., Manasijević, D.,& Živković, D.. (2013). Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System. in Journal of Materials Engineering and Performance Springer, New York., 22(8), 2343-2350. https://doi.org/10.1007/s11665-013-0493-3
Minić D, Premović M, Kolarevic M, Ćosović V, Manasijević D, Živković D. Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System. in Journal of Materials Engineering and Performance. 2013;22(8):2343-2350. doi:10.1007/s11665-013-0493-3 .
Minić, Duško, Premović, Milena, Kolarevic, Milan, Ćosović, Vladan, Manasijević, Dragan, Živković, Dragana, "Description of the Liquidus Surface and Characterization of Alloys of the Ternary Bi-Cu-In System" in Journal of Materials Engineering and Performance, 22, no. 8 (2013):2343-2350, https://doi.org/10.1007/s11665-013-0493-3 . .