Приказ свих података о документуАпстракт
Cobalt–chromium–molybdenum (CoCrMo) alloys are known for medical use due to their biocompatibility, corrosion and wear resistance. The chemical and phase composition, as well as microstructure of the alloy directly affect the mechanical properties. In this investigation, CoCrMo alloy samples were obtained by vacuum precise casting. The procedure of melting and casting process as well as their parameters are given. Molds fabricated of copper, gray iron, steel, ceramics and graphite were used during the casting process. In this way, the cooling rate influence on the obtained microstructure was examined. Besides, different casting temperatures (1400°C, 1450°C and 1500°C) were applied for each kind of mold. After metallographic preparation, the microstructure was examined on the cross section of samples by optical microscopy. The obtained results show that by increasing the cooling rate, the microstructure of samples become finer and more homogeneous.
Кључне речи:
CoCrMo alloy / vacuum precise casting / cooling rateИзвор:
Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina, 2023, 221-225Издавач:
- Association of Metallurgical Engineers of Serbia (AMES)
Финансирање / пројекти:
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200026 (Универзитет у Београду, Институт за хемију, технологију и металургију - ИХТМ) (RS-MESTD-inst-2020-200026)
- Министарство науке, технолошког развоја и иновација Републике Србије, институционално финансирање - 200023 (Институт за технологију нуклеарних и других минералних сировина - ИТНМС, Београд) (RS-MESTD-inst-2020-200023)
Институција/група
IHTMTY - CONF AU - Patarić, Aleksandra AU - Marković, Gordana AU - Đorđević, Nataša G. AU - Mihajlović, Slavica AU - Mihailović, Marija PY - 2023 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/6248 AB - Cobalt–chromium–molybdenum (CoCrMo) alloys are known for medical use due to their biocompatibility, corrosion and wear resistance. The chemical and phase composition, as well as microstructure of the alloy directly affect the mechanical properties. In this investigation, CoCrMo alloy samples were obtained by vacuum precise casting. The procedure of melting and casting process as well as their parameters are given. Molds fabricated of copper, gray iron, steel, ceramics and graphite were used during the casting process. In this way, the cooling rate influence on the obtained microstructure was examined. Besides, different casting temperatures (1400°C, 1450°C and 1500°C) were applied for each kind of mold. After metallographic preparation, the microstructure was examined on the cross section of samples by optical microscopy. The obtained results show that by increasing the cooling rate, the microstructure of samples become finer and more homogeneous. PB - Association of Metallurgical Engineers of Serbia (AMES) C3 - Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina T1 - Microstructure assessment of Co alloy intended for dentistry SP - 221 EP - 225 UR - https://hdl.handle.net/21.15107/rcub_cer_6248 ER -
@conference{ author = "Patarić, Aleksandra and Marković, Gordana and Đorđević, Nataša G. and Mihajlović, Slavica and Mihailović, Marija", year = "2023", abstract = "Cobalt–chromium–molybdenum (CoCrMo) alloys are known for medical use due to their biocompatibility, corrosion and wear resistance. The chemical and phase composition, as well as microstructure of the alloy directly affect the mechanical properties. In this investigation, CoCrMo alloy samples were obtained by vacuum precise casting. The procedure of melting and casting process as well as their parameters are given. Molds fabricated of copper, gray iron, steel, ceramics and graphite were used during the casting process. In this way, the cooling rate influence on the obtained microstructure was examined. Besides, different casting temperatures (1400°C, 1450°C and 1500°C) were applied for each kind of mold. After metallographic preparation, the microstructure was examined on the cross section of samples by optical microscopy. The obtained results show that by increasing the cooling rate, the microstructure of samples become finer and more homogeneous.", publisher = "Association of Metallurgical Engineers of Serbia (AMES)", journal = "Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina", title = "Microstructure assessment of Co alloy intended for dentistry", pages = "221-225", url = "https://hdl.handle.net/21.15107/rcub_cer_6248" }
Patarić, A., Marković, G., Đorđević, N. G., Mihajlović, S.,& Mihailović, M.. (2023). Microstructure assessment of Co alloy intended for dentistry. in Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina Association of Metallurgical Engineers of Serbia (AMES)., 221-225. https://hdl.handle.net/21.15107/rcub_cer_6248
Patarić A, Marković G, Đorđević NG, Mihajlović S, Mihailović M. Microstructure assessment of Co alloy intended for dentistry. in Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina. 2023;:221-225. https://hdl.handle.net/21.15107/rcub_cer_6248 .
Patarić, Aleksandra, Marković, Gordana, Đorđević, Nataša G., Mihajlović, Slavica, Mihailović, Marija, "Microstructure assessment of Co alloy intended for dentistry" in Proceedings of the 5th Metallurgical and Materials Engineering Congress of South-East Europe, 7-10.06.2023, Trebinje, Bosnia and Herzegovina (2023):221-225, https://hdl.handle.net/21.15107/rcub_cer_6248 .