CER - Central Repository
Institute of Chemistry, Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine

Authorized Users Only
2022
Authors
Negrojević, Luka
Lončar, Aleksandar
Maksimović, Jelena
Anić, Slobodan
Čupić, Željko
Kolar-Anić, Ljiljana
Pejić, Nataša
Article (Published version)
Metadata
Show full item record
Abstract
A kinetic method for the determination of l-tyrosine (Tyr) by analyte pulse perturbation, caused by different amounts of Tyr, in the Bray–Liebhafsky (BL) oscillatory reaction realized in a continuous-flow stirred tank reactor, is proposed. For such purposes, the BL oscillating reaction was kept in a stable non-equilibrium stationary state close to the bifurcation point and was used as the matrix reaction system. Under optimum reaction conditions, the linear relationship between the kinetic parameters, Δτ2 (the period between first two oscillations that appear after applied perturbation) as well as τend (the time elapsed between the perturbation of the BL reaction by Tyr and the termination of the oscillatory phase) and the Tyr concentrations is obtained over the ranges 1.1 × 10− 6 − 9.2 × 10− 6 mol L− 1 and 1.1 × 10− 6 − 1.4 × 10− 5 mol L− 1, with the limit of detections of 6.6 × 10− 7 mol L− 1 and 6.4 × 10− 7 mol L− 1. The described method that relies on a simple instrumental set-up, ...has been successfully applied to the determination of Tyr in a dietary supplement. Some aspects of the possible mechanism of Tyr action on the BL oscillator are discussed.

Keywords:
Bray–Liebhafsky oscillatory reaction / CSTR / Dietary supplement / Kinetic method / Perturbation technique / Quantitative determination of tyrosine
Source:
Reaction Kinetics, Mechanisms and Catalysis, 2022, 135, 1147-1162
Publisher:
  • Springer
Funding / projects:
  • NES - Physicochemical aspects of rhythmicity in neuroendocrine systems: Dynamic and kinetic investigations of underlying reaction networks and their main compounds (RS-7743504)
  • Dynamics of nonlinear physicochemical and biochemical systems with modeling and predicting of their behavior under nonequilibrium conditions (RS-172015)
  • Nanostructured Functional and Composite Materials in Catalytic and Sorption Processes (RS-45001)
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200146 (University of Belgrade, Faculty of Physical Chemistry) (RS-200146)
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200026 (University of Belgrade, Institute of Chemistry, Technology and Metallurgy - IChTM) (RS-200026)
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200161 (University of Belgrade, Faculty of Pharmacy) (RS-200161)

DOI: 10.1007/s11144-021-02130-5

ISSN: 1878-5190

WoS: 000739750300001

Scopus: 2-s2.0-85122412741
[ Google Scholar ]
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/5253
Collections
  • Radovi istraživača / Researchers' publications
  • NES
Institution/Community
IHTM
TY  - JOUR
AU  - Negrojević, Luka
AU  - Lončar, Aleksandar
AU  - Maksimović, Jelena
AU  - Anić, Slobodan
AU  - Čupić, Željko
AU  - Kolar-Anić, Ljiljana
AU  - Pejić, Nataša
PY  - 2022
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/5253
AB  - A kinetic method for the determination of l-tyrosine (Tyr) by analyte pulse perturbation, caused by different amounts of Tyr, in the Bray–Liebhafsky (BL) oscillatory reaction realized in a continuous-flow stirred tank reactor, is proposed. For such purposes, the BL oscillating reaction was kept in a stable non-equilibrium stationary state close to the bifurcation point and was used as the matrix reaction system. Under optimum reaction conditions, the linear relationship between the kinetic parameters, Δτ2 (the period between first two oscillations that appear after applied perturbation) as well as τend (the time elapsed between the perturbation of the BL reaction by Tyr and the termination of the oscillatory phase) and the Tyr concentrations is obtained over the ranges 1.1 × 10− 6 − 9.2 × 10− 6 mol L− 1 and 1.1 × 10− 6 − 1.4 × 10− 5 mol L− 1, with the limit of detections of 6.6 × 10− 7 mol L− 1 and 6.4 × 10− 7 mol L− 1. The described method that relies on a simple instrumental set-up, has been successfully applied to the determination of Tyr in a dietary supplement. Some aspects of the possible mechanism of Tyr action on the BL oscillator are discussed.
PB  - Springer
T2  - Reaction Kinetics, Mechanisms and Catalysis
T1  - Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine
VL  - 135
SP  - 1147
EP  - 1162
DO  - 10.1007/s11144-021-02130-5
ER  - 
@article{
author = "Negrojević, Luka and Lončar, Aleksandar and Maksimović, Jelena and Anić, Slobodan and Čupić, Željko and Kolar-Anić, Ljiljana and Pejić, Nataša",
year = "2022",
abstract = "A kinetic method for the determination of l-tyrosine (Tyr) by analyte pulse perturbation, caused by different amounts of Tyr, in the Bray–Liebhafsky (BL) oscillatory reaction realized in a continuous-flow stirred tank reactor, is proposed. For such purposes, the BL oscillating reaction was kept in a stable non-equilibrium stationary state close to the bifurcation point and was used as the matrix reaction system. Under optimum reaction conditions, the linear relationship between the kinetic parameters, Δτ2 (the period between first two oscillations that appear after applied perturbation) as well as τend (the time elapsed between the perturbation of the BL reaction by Tyr and the termination of the oscillatory phase) and the Tyr concentrations is obtained over the ranges 1.1 × 10− 6 − 9.2 × 10− 6 mol L− 1 and 1.1 × 10− 6 − 1.4 × 10− 5 mol L− 1, with the limit of detections of 6.6 × 10− 7 mol L− 1 and 6.4 × 10− 7 mol L− 1. The described method that relies on a simple instrumental set-up, has been successfully applied to the determination of Tyr in a dietary supplement. Some aspects of the possible mechanism of Tyr action on the BL oscillator are discussed.",
publisher = "Springer",
journal = "Reaction Kinetics, Mechanisms and Catalysis",
title = "Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine",
volume = "135",
pages = "1147-1162",
doi = "10.1007/s11144-021-02130-5"
}
Negrojević, L., Lončar, A., Maksimović, J., Anić, S., Čupić, Ž., Kolar-Anić, L.,& Pejić, N.. (2022). Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine. in Reaction Kinetics, Mechanisms and Catalysis
Springer., 135, 1147-1162.
https://doi.org/10.1007/s11144-021-02130-5
Negrojević L, Lončar A, Maksimović J, Anić S, Čupić Ž, Kolar-Anić L, Pejić N. Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine. in Reaction Kinetics, Mechanisms and Catalysis. 2022;135:1147-1162.
doi:10.1007/s11144-021-02130-5 .
Negrojević, Luka, Lončar, Aleksandar, Maksimović, Jelena, Anić, Slobodan, Čupić, Željko, Kolar-Anić, Ljiljana, Pejić, Nataša, "Bray–Liebhafsky oscillatory reaction in a continuous-flow stirred tank reactor as the matrix system for determination of tyrosine" in Reaction Kinetics, Mechanisms and Catalysis, 135 (2022):1147-1162,
https://doi.org/10.1007/s11144-021-02130-5 . .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB