POPs Level of Environmental Sample in Serbia
Само за регистроване кориснике
2017
Аутори
Nakano, Takeshi
Beškoski, Vladimir

Haga, Y
Matsumura, C.
Miletić, Srđan

Ilić, Mila

Milić, Jelena

Vrvić, Miroslav

Конференцијски прилог (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
Persistent organic pollutants (POPs) are chemicals that persist in the environment, bioaccumulate through the food web, and exhibit toxic effects that may threaten the health of humans and wildlife. Active air sampler (AAS) is useful in the monitoring of POPs in air. Air sample was collected for POPs analysis using a filter/adsorbent.AAS using conventional air samplers requires pumps, filter/adsorbent, and source of electricity. This type ofsampling can be costly and not always feasible, especially if several simultaneous sampling are required at different locations. There is an incentive therefore to further develop passive air sampler (PAS). The mechanism of uptake in PAS is based on the molecular diffusion from air to passive sampling medium. PAS are capable of time-integrated sampling with relatively low cost and simple operation, which is independent from power supply and free of noise. Therefore PAS is expected as a simultaneous monitoring in numerous locations. Various researche...rs investigate basic research. We reported sampling rate of PCB congeners in same location at the same period using PAS and AAS in previous study.
Кључне речи:
Persistent organic pollutants / POPs / Active air sampler / air samplingИзвор:
26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan, 2017, 1E-09-Издавач:
- Japan Society for Environmental Chemistry
Институција/група
IHTMTY - CONF AU - Nakano, Takeshi AU - Beškoski, Vladimir AU - Haga, Y AU - Matsumura, C. AU - Miletić, Srđan AU - Ilić, Mila AU - Milić, Jelena AU - Vrvić, Miroslav PY - 2017 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/5099 AB - Persistent organic pollutants (POPs) are chemicals that persist in the environment, bioaccumulate through the food web, and exhibit toxic effects that may threaten the health of humans and wildlife. Active air sampler (AAS) is useful in the monitoring of POPs in air. Air sample was collected for POPs analysis using a filter/adsorbent.AAS using conventional air samplers requires pumps, filter/adsorbent, and source of electricity. This type ofsampling can be costly and not always feasible, especially if several simultaneous sampling are required at different locations. There is an incentive therefore to further develop passive air sampler (PAS). The mechanism of uptake in PAS is based on the molecular diffusion from air to passive sampling medium. PAS are capable of time-integrated sampling with relatively low cost and simple operation, which is independent from power supply and free of noise. Therefore PAS is expected as a simultaneous monitoring in numerous locations. Various researchers investigate basic research. We reported sampling rate of PCB congeners in same location at the same period using PAS and AAS in previous study. PB - Japan Society for Environmental Chemistry C3 - 26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan T1 - POPs Level of Environmental Sample in Serbia SP - 1E-09 UR - https://hdl.handle.net/21.15107/rcub_cer_5099 ER -
@conference{ author = "Nakano, Takeshi and Beškoski, Vladimir and Haga, Y and Matsumura, C. and Miletić, Srđan and Ilić, Mila and Milić, Jelena and Vrvić, Miroslav", year = "2017", abstract = "Persistent organic pollutants (POPs) are chemicals that persist in the environment, bioaccumulate through the food web, and exhibit toxic effects that may threaten the health of humans and wildlife. Active air sampler (AAS) is useful in the monitoring of POPs in air. Air sample was collected for POPs analysis using a filter/adsorbent.AAS using conventional air samplers requires pumps, filter/adsorbent, and source of electricity. This type ofsampling can be costly and not always feasible, especially if several simultaneous sampling are required at different locations. There is an incentive therefore to further develop passive air sampler (PAS). The mechanism of uptake in PAS is based on the molecular diffusion from air to passive sampling medium. PAS are capable of time-integrated sampling with relatively low cost and simple operation, which is independent from power supply and free of noise. Therefore PAS is expected as a simultaneous monitoring in numerous locations. Various researchers investigate basic research. We reported sampling rate of PCB congeners in same location at the same period using PAS and AAS in previous study.", publisher = "Japan Society for Environmental Chemistry", journal = "26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan", title = "POPs Level of Environmental Sample in Serbia", pages = "1E-09", url = "https://hdl.handle.net/21.15107/rcub_cer_5099" }
Nakano, T., Beškoski, V., Haga, Y., Matsumura, C., Miletić, S., Ilić, M., Milić, J.,& Vrvić, M.. (2017). POPs Level of Environmental Sample in Serbia. in 26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan Japan Society for Environmental Chemistry., 1E-09. https://hdl.handle.net/21.15107/rcub_cer_5099
Nakano T, Beškoski V, Haga Y, Matsumura C, Miletić S, Ilić M, Milić J, Vrvić M. POPs Level of Environmental Sample in Serbia. in 26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan. 2017;:1E-09. https://hdl.handle.net/21.15107/rcub_cer_5099 .
Nakano, Takeshi, Beškoski, Vladimir, Haga, Y, Matsumura, C., Miletić, Srđan, Ilić, Mila, Milić, Jelena, Vrvić, Miroslav, "POPs Level of Environmental Sample in Serbia" in 26th Symposium on Environmental Chemistry Program and Abstracts,June 7-9, 2017, Shizuoka, Japan (2017):1E-09, https://hdl.handle.net/21.15107/rcub_cer_5099 .