Recharging process of commercial floating-gate MOS transistor in dosimetry application
Аутори
Ilić, Stefan D.
Andjelković, Marko S.
Duane, Russell

Palma, Alberto J.

Sarajlić, Milija

Stanković, Srboljub
Ristić, Goran

Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
We investigated the recharging process of commercial floating gate device (EPAD) during the six different dose rates and ten irradiation cycles with the highest dose rate. Dose rate dependence of the floating gate dosimeter was observed from 1 Gy/h to 26 Gy/h (H2O). There is no change of the dosimetric characteristic with a constant dose rate of 26 Gy/h for ten cycles. The absorbed dose does not affect the drift of the threshold voltage readings after the irradiation steps. The reprogramming characteristic is not degrading with the absorbed dose for the ten irradiation cycles, giving the promising potential in the application for dosimetric purposes.
Кључне речи:
Floating gate / Radiation sensor / EPAD / Recharging / Programming cell / Non-volatile memoryИзвор:
Microelectronics Reliability, 2021, 126, 114322-Издавач:
- Elsevier
Финансирање / пројекти:
- WIDESPREAD-2018-3-TWINNING
- Заједничка истраживања мерења и утицаја јонизујућег и УВ зрачења у области медицине и заштите животне средине (RS-43011)
- Министарство просвете, науке и технолошког развоја Републике Србије, Уговор бр. 200026 (Универзитет у Београду, Институт за хемију, технологију и металургију - ИХТМ) (RS-200026)
- ELICSIR - Enhancement of Sceintific Excellence and Innovation Potential in Electronic Instrumentation for Ionising Radiation Environments (EU-857558)
DOI: 10.1016/j.microrel.2021.114322
ISSN: 0026-2714
WoS: 000733412800004
Scopus: 2-s2.0-85120850474
Институција/група
IHTMTY - JOUR AU - Ilić, Stefan D. AU - Andjelković, Marko S. AU - Duane, Russell AU - Palma, Alberto J. AU - Sarajlić, Milija AU - Stanković, Srboljub AU - Ristić, Goran PY - 2021 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/4911 AB - We investigated the recharging process of commercial floating gate device (EPAD) during the six different dose rates and ten irradiation cycles with the highest dose rate. Dose rate dependence of the floating gate dosimeter was observed from 1 Gy/h to 26 Gy/h (H2O). There is no change of the dosimetric characteristic with a constant dose rate of 26 Gy/h for ten cycles. The absorbed dose does not affect the drift of the threshold voltage readings after the irradiation steps. The reprogramming characteristic is not degrading with the absorbed dose for the ten irradiation cycles, giving the promising potential in the application for dosimetric purposes. PB - Elsevier T2 - Microelectronics Reliability T1 - Recharging process of commercial floating-gate MOS transistor in dosimetry application VL - 126 SP - 114322 DO - 10.1016/j.microrel.2021.114322 ER -
@article{ author = "Ilić, Stefan D. and Andjelković, Marko S. and Duane, Russell and Palma, Alberto J. and Sarajlić, Milija and Stanković, Srboljub and Ristić, Goran", year = "2021", abstract = "We investigated the recharging process of commercial floating gate device (EPAD) during the six different dose rates and ten irradiation cycles with the highest dose rate. Dose rate dependence of the floating gate dosimeter was observed from 1 Gy/h to 26 Gy/h (H2O). There is no change of the dosimetric characteristic with a constant dose rate of 26 Gy/h for ten cycles. The absorbed dose does not affect the drift of the threshold voltage readings after the irradiation steps. The reprogramming characteristic is not degrading with the absorbed dose for the ten irradiation cycles, giving the promising potential in the application for dosimetric purposes.", publisher = "Elsevier", journal = "Microelectronics Reliability", title = "Recharging process of commercial floating-gate MOS transistor in dosimetry application", volume = "126", pages = "114322", doi = "10.1016/j.microrel.2021.114322" }
Ilić, S. D., Andjelković, M. S., Duane, R., Palma, A. J., Sarajlić, M., Stanković, S.,& Ristić, G.. (2021). Recharging process of commercial floating-gate MOS transistor in dosimetry application. in Microelectronics Reliability Elsevier., 126, 114322. https://doi.org/10.1016/j.microrel.2021.114322
Ilić SD, Andjelković MS, Duane R, Palma AJ, Sarajlić M, Stanković S, Ristić G. Recharging process of commercial floating-gate MOS transistor in dosimetry application. in Microelectronics Reliability. 2021;126:114322. doi:10.1016/j.microrel.2021.114322 .
Ilić, Stefan D., Andjelković, Marko S., Duane, Russell, Palma, Alberto J., Sarajlić, Milija, Stanković, Srboljub, Ristić, Goran, "Recharging process of commercial floating-gate MOS transistor in dosimetry application" in Microelectronics Reliability, 126 (2021):114322, https://doi.org/10.1016/j.microrel.2021.114322 . .