Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium
Authorized Users Only
1992
Authors
Vuković, MarijanČukman, Dunja
Milun, Milorad

Atanasoska, Ljiljana L.
Atanasoski, Radoslav T.
Article (Published version)

Metadata
Show full item recordAbstract
The anodic behaviour of galvanically plated ruthenium-iridium coatings on titanium was investigated. The dependence of the Tafel slopes and the stability of the coatings for the oxygen evolution reaction in sulphuric acid on the electrode composition was established. A change in the Tafel slope from 33 to 90 mV per decade on going from pure ruthenium to pure iridium was found. The presence of 40% Ir in the coating yielded 300 times higher stability in comparison with the coating of pure ruthenium. In addition, a square-wave pulsing between -0.25 and 1.25 V vs. the saturated calomel electrode produced an oxide film with electrochromic properties which were directly related to the charge enhancement factor of the grown oxide.
Keywords:
ruthenium-iridium coatings / titanium / oxigen / sulphuric acid / electrodeSource:
Journal of Electroanalytical Chemistry, 1992, 330, 1-2, 663-673Publisher:
- Elsevier
Funding / projects:
- The Yugoslav Federal Project P-96
- The Scientific Fund of Serbia
- The Ministry of Science, Republic of Croatia (Grant l-03-056)
- The Ministry of Science, Republic of Croatia ( Grant l-07-162 )
Collections
Institution/Community
IHTMTY - JOUR AU - Vuković, Marijan AU - Čukman, Dunja AU - Milun, Milorad AU - Atanasoska, Ljiljana L. AU - Atanasoski, Radoslav T. PY - 1992 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/4739 AB - The anodic behaviour of galvanically plated ruthenium-iridium coatings on titanium was investigated. The dependence of the Tafel slopes and the stability of the coatings for the oxygen evolution reaction in sulphuric acid on the electrode composition was established. A change in the Tafel slope from 33 to 90 mV per decade on going from pure ruthenium to pure iridium was found. The presence of 40% Ir in the coating yielded 300 times higher stability in comparison with the coating of pure ruthenium. In addition, a square-wave pulsing between -0.25 and 1.25 V vs. the saturated calomel electrode produced an oxide film with electrochromic properties which were directly related to the charge enhancement factor of the grown oxide. PB - Elsevier T2 - Journal of Electroanalytical Chemistry T1 - Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium VL - 330 IS - 1-2 SP - 663 EP - 673 DO - 10.1016/0022-0728(92)80335-2 ER -
@article{ author = "Vuković, Marijan and Čukman, Dunja and Milun, Milorad and Atanasoska, Ljiljana L. and Atanasoski, Radoslav T.", year = "1992", abstract = "The anodic behaviour of galvanically plated ruthenium-iridium coatings on titanium was investigated. The dependence of the Tafel slopes and the stability of the coatings for the oxygen evolution reaction in sulphuric acid on the electrode composition was established. A change in the Tafel slope from 33 to 90 mV per decade on going from pure ruthenium to pure iridium was found. The presence of 40% Ir in the coating yielded 300 times higher stability in comparison with the coating of pure ruthenium. In addition, a square-wave pulsing between -0.25 and 1.25 V vs. the saturated calomel electrode produced an oxide film with electrochromic properties which were directly related to the charge enhancement factor of the grown oxide.", publisher = "Elsevier", journal = "Journal of Electroanalytical Chemistry", title = "Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium", volume = "330", number = "1-2", pages = "663-673", doi = "10.1016/0022-0728(92)80335-2" }
Vuković, M., Čukman, D., Milun, M., Atanasoska, L. L.,& Atanasoski, R. T.. (1992). Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium. in Journal of Electroanalytical Chemistry Elsevier., 330(1-2), 663-673. https://doi.org/10.1016/0022-0728(92)80335-2
Vuković M, Čukman D, Milun M, Atanasoska LL, Atanasoski RT. Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium. in Journal of Electroanalytical Chemistry. 1992;330(1-2):663-673. doi:10.1016/0022-0728(92)80335-2 .
Vuković, Marijan, Čukman, Dunja, Milun, Milorad, Atanasoska, Ljiljana L., Atanasoski, Radoslav T., "Anodic stability and electrochromism of electrodeposited ruthenium-iridium coatings on titanium" in Journal of Electroanalytical Chemistry, 330, no. 1-2 (1992):663-673, https://doi.org/10.1016/0022-0728(92)80335-2 . .