Приказ основних података о документу

dc.creatorLović, Jelena
dc.creatorLađarević, Jelena
dc.creatorTrišović, Nemanja
dc.creatorAndrić, Filip
dc.creatorMladenović, Aleksandar R.
dc.creatorMijin, Dušan
dc.creatorVuković, Dragan
dc.creatorPetrović, Slobodan D.
dc.creatorAvramov Ivić, Milka
dc.date.accessioned2021-02-19T15:28:29Z
dc.date.available2021-02-19T15:28:29Z
dc.date.issued2021
dc.identifier.issn0026-9247
dc.identifier.urihttps://cer.ihtm.bg.ac.rs/handle/123456789/4246
dc.description.abstractThe electrochemical characterization of sertraline at gold electrode was examined by cyclic voltammetry measurements (CV) in pH 8.4 bicarbonate buffer. Then Au electrode was evaluated for the quantitative determination of sertraline using square wave voltammetry (SWV). To enhance the sensitivity during the drug determination, (2-hydroxypropyl)-β-cyclodextrin (HPβCD) and β-cyclodextrin (βCD) inclusion complexes were employed. Using the proposed SWV technique, the anodic current peak was linear within a concentration range of 0.1–0.5 μM with a limit of detection (LOD) of 2.0 × 10–8 M and a limit of quantification (LOQ) of 6.7 × 10–8 M. In the case of inclusion complex of the sertraline with HPβCD, a good linearity range of 0.1–0.9 μM was obtained with a LOD of 2.6 × 10–8 M and a LOQ of 8.8 × 10–8 M. The gold electrode revealed the same linearity range for inclusion complex of the sertraline with βCD with a LOD and a LOQ being 2.6 × 10–8 and 8.6 × 10–8 M, respectively. Comparing the regression equations, it can be concluded that the sensitivity in the presence of inclusion complex can be up to 5 times higher. The applicability of the developed method was confirmed by the analysis of this drug in pharmaceutical formulation and in human serum spiked with sertraline standard. The comparison to HPLC method was successfully performed.sr
dc.language.isoensr
dc.publisherSpringersr
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200135/RS//sr
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200026/RS//sr
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200168/RS//sr
dc.rightsrestrictedAccesssr
dc.sourceMonatshefte für Chemie - Chemical Monthlysr
dc.subjectCyclodextrinessr
dc.subjectElectrochemistrysr
dc.subjectHuman serumsr
dc.subjectPharmaceutical formulationsr
dc.subjectVoltammetrysr
dc.titleElectrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solutionsr
dc.typearticlesr
dc.rights.licenseARRsr
dcterms.abstractЛовић, Јелена; Лађаревић, Јелена; Тришовић, Немања; Aндрић, Филип; Младеновић, Aлександар Р.; Мијин, Душан; Вуковић, Драган; Петровић, Слободан Д.; Aврамов - Ивић, Милка; Елецтроцхемицал детерминатион оф сертралине ин пхармацеутицал формулатион анд серум усинг а голд елецтроде ин а пХ 8.4 бицарбонате солутион; Елецтроцхемицал детерминатион оф сертралине ин пхармацеутицал формулатион анд серум усинг а голд елецтроде ин а пХ 8.4 бицарбонате солутион;
dc.citation.spage185
dc.citation.epage192
dc.citation.rankM23~
dc.identifier.doi10.1007/s00706-021-02745-3
dc.identifier.wos000619396100001
dc.type.versionpublishedVersionsr


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу