Приказ основних података о документу

dc.creatorStanković, Dalibor M.
dc.creatorMilanović, Zorana
dc.creatorŠvorc, Ljubomir
dc.creatorStanković, Vesna
dc.creatorJanković, Drina
dc.creatorMirković, Marija
dc.creatorVranješ-Đurić, Sanja
dc.date.accessioned2021-02-11T10:53:17Z
dc.date.available2021-02-11T10:53:17Z
dc.date.issued2021
dc.identifier.issn0925-9635
dc.identifier.urihttps://cer.ihtm.bg.ac.rs/handle/123456789/4224
dc.description.abstractThis work presents advanced electrochemical platform based on screen printed diamond electrode (SPDE) system for the single drop “point-of-care” testing. Proposed approach was applied for the quantification of doxorubicin hydrochloride (DOX) in biological fluids and pharmaceutical product. Using a single drop (~30 μL) of the tested solution at the electrode surface, DOX showed high electroactivity over a wide range of pHs. In these conditions, single oval shaped, well-defined and pH dependent oxidation peak was observed in the potential range from 0.5 V to 1.3 V. In the reverse scan, two cathodic peaks, were noted – around 0.3 V and – 0.5 V. Similarly, first reduction peak was pH dependent, while second one was independent in the studied range. Experimental conditions for DOX quantification were optimized and natures of the electrode reactions were investigated. Working linear range obtained for DOX detection was from 0.1 to 2.5 μM. Diffusion controlled electrode reaction reveal long life time of the proposed electrode as well high potential for practical application. Developed procedure was successfully applied for the DOX analysis in biological fluids – urine and pharmaceutical formulation. Obtained results clearly indicated that given procedure can be easily implemented for pharmaceutical control and medical analysis, in both, laboratory and field conditionssr
dc.language.isoensr
dc.publisherElseviersr
dc.relationThe Ministry of Education, Science and Technological Development of the Republic of Serbia through Eureka project E! 13303 MED-BIO-TESTsr
dc.relationThe Grant Agency of the Slovak Republic VEGA (grant no. 1/0159/20)sr
dc.rightsrestrictedAccesssr
dc.sourceDiamond and Related Materialssr
dc.subjectCytostatic drugsr
dc.subjectScreen printed diamond electrodesr
dc.subjectSingle drop detectionsr
dc.subject“Point-of-care” applicationsr
dc.titleScreen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical productsr
dc.typearticlesr
dc.rights.licenseARRsr
dcterms.abstractМилановић, Зорана; Станковић, Далибор М.; Шворц, Љубомир; Јанковић, Дрина; Мирковић, Марија; Врањеш-Ђурић, Сања; Станковић, Весна;
dc.citation.volume113
dc.citation.spage108277
dc.citation.rankM22~
dc.identifier.doi10.1016/j.diamond.2021.108277
dc.identifier.scopus2-s2.0-85099612809
dc.identifier.wos000623246800006
dc.type.versionpublishedVersionsr


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу