Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product
Authorized Users Only
2021
Authors
Stanković, Dalibor M.
Milanović, Zorana
Švorc, Ljubomir
Stanković, Vesna

Janković, Drina

Mirković, Marija

Vranješ-Đurić, Sanja

Article (Published version)

Metadata
Show full item recordAbstract
This work presents advanced electrochemical platform based on screen printed diamond electrode (SPDE) system for the single drop “point-of-care” testing. Proposed approach was applied for the quantification of doxorubicin hydrochloride (DOX) in biological fluids and pharmaceutical product. Using a single drop (~30 μL) of the tested solution at the electrode surface, DOX showed high electroactivity over a wide range of pHs. In these conditions, single oval shaped, well-defined and pH dependent oxidation peak was observed in the potential range from 0.5 V to 1.3 V. In the reverse scan, two cathodic peaks, were noted – around 0.3 V and – 0.5 V. Similarly, first reduction peak was pH dependent, while second one was independent in the studied range. Experimental conditions for DOX quantification were optimized and natures of the electrode reactions were investigated. Working linear range obtained for DOX detection was from 0.1 to 2.5 μM. Diffusion controlled electrode reaction reveal long l...ife time of the proposed electrode as well high potential for practical application. Developed procedure was successfully applied for the DOX analysis in biological fluids – urine and pharmaceutical formulation. Obtained results clearly indicated that given procedure can be easily implemented for pharmaceutical control and medical analysis, in both, laboratory and field conditions
Keywords:
Cytostatic drug / Screen printed diamond electrode / Single drop detection / “Point-of-care” applicationSource:
Diamond and Related Materials, 2021, 113, 108277-Publisher:
- Elsevier
Funding / projects:
- The Ministry of Education, Science and Technological Development of the Republic of Serbia through Eureka project E! 13303 MED-BIO-TEST
- The Grant Agency of the Slovak Republic VEGA (grant no. 1/0159/20)
DOI: 10.1016/j.diamond.2021.108277
ISSN: 0925-9635
WoS: 000623246800006
Scopus: 2-s2.0-85099612809
Collections
Institution/Community
IHTMTY - JOUR AU - Stanković, Dalibor M. AU - Milanović, Zorana AU - Švorc, Ljubomir AU - Stanković, Vesna AU - Janković, Drina AU - Mirković, Marija AU - Vranješ-Đurić, Sanja PY - 2021 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/4224 AB - This work presents advanced electrochemical platform based on screen printed diamond electrode (SPDE) system for the single drop “point-of-care” testing. Proposed approach was applied for the quantification of doxorubicin hydrochloride (DOX) in biological fluids and pharmaceutical product. Using a single drop (~30 μL) of the tested solution at the electrode surface, DOX showed high electroactivity over a wide range of pHs. In these conditions, single oval shaped, well-defined and pH dependent oxidation peak was observed in the potential range from 0.5 V to 1.3 V. In the reverse scan, two cathodic peaks, were noted – around 0.3 V and – 0.5 V. Similarly, first reduction peak was pH dependent, while second one was independent in the studied range. Experimental conditions for DOX quantification were optimized and natures of the electrode reactions were investigated. Working linear range obtained for DOX detection was from 0.1 to 2.5 μM. Diffusion controlled electrode reaction reveal long life time of the proposed electrode as well high potential for practical application. Developed procedure was successfully applied for the DOX analysis in biological fluids – urine and pharmaceutical formulation. Obtained results clearly indicated that given procedure can be easily implemented for pharmaceutical control and medical analysis, in both, laboratory and field conditions PB - Elsevier T2 - Diamond and Related Materials T1 - Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product VL - 113 SP - 108277 DO - 10.1016/j.diamond.2021.108277 ER -
@article{ author = "Stanković, Dalibor M. and Milanović, Zorana and Švorc, Ljubomir and Stanković, Vesna and Janković, Drina and Mirković, Marija and Vranješ-Đurić, Sanja", year = "2021", abstract = "This work presents advanced electrochemical platform based on screen printed diamond electrode (SPDE) system for the single drop “point-of-care” testing. Proposed approach was applied for the quantification of doxorubicin hydrochloride (DOX) in biological fluids and pharmaceutical product. Using a single drop (~30 μL) of the tested solution at the electrode surface, DOX showed high electroactivity over a wide range of pHs. In these conditions, single oval shaped, well-defined and pH dependent oxidation peak was observed in the potential range from 0.5 V to 1.3 V. In the reverse scan, two cathodic peaks, were noted – around 0.3 V and – 0.5 V. Similarly, first reduction peak was pH dependent, while second one was independent in the studied range. Experimental conditions for DOX quantification were optimized and natures of the electrode reactions were investigated. Working linear range obtained for DOX detection was from 0.1 to 2.5 μM. Diffusion controlled electrode reaction reveal long life time of the proposed electrode as well high potential for practical application. Developed procedure was successfully applied for the DOX analysis in biological fluids – urine and pharmaceutical formulation. Obtained results clearly indicated that given procedure can be easily implemented for pharmaceutical control and medical analysis, in both, laboratory and field conditions", publisher = "Elsevier", journal = "Diamond and Related Materials", title = "Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product", volume = "113", pages = "108277", doi = "10.1016/j.diamond.2021.108277" }
Stanković, D. M., Milanović, Z., Švorc, L., Stanković, V., Janković, D., Mirković, M.,& Vranješ-Đurić, S.. (2021). Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product. in Diamond and Related Materials Elsevier., 113, 108277. https://doi.org/10.1016/j.diamond.2021.108277
Stanković DM, Milanović Z, Švorc L, Stanković V, Janković D, Mirković M, Vranješ-Đurić S. Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product. in Diamond and Related Materials. 2021;113:108277. doi:10.1016/j.diamond.2021.108277 .
Stanković, Dalibor M., Milanović, Zorana, Švorc, Ljubomir, Stanković, Vesna, Janković, Drina, Mirković, Marija, Vranješ-Đurić, Sanja, "Screen printed diamond electrode as efficient “point-of-care” platform for submicromolar determination of cytostatic drug in biological fluids and pharmaceutical product" in Diamond and Related Materials, 113 (2021):108277, https://doi.org/10.1016/j.diamond.2021.108277 . .