Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola

The role of ruthenium in perovskite-type mixed oxide in the electrochemical degradation of 4-nitrophenol

Thumbnail
2020
bitstream_18683.pdf (283.4Kb)
Authors
Mojović, Zorica
Petrović, Srđan
Rožić, Ljiljana
Article (Published version)
Metadata
Show full item record
Abstract
U ovom radu su okarakterisani novi elektrodni materijali na bazi perovskita za detekciju 4-nitrofenola. Mešoviti oksidi perovskitnog tipa hemijske formule La0.7Sr0.3Cr1-XRuXO3 (X= 0; 0.05) su sintetisani konvencionalnim keramičkim postupkom. Rezultati rendgenske difrakcione analize su pokazali da je sintetizovani sistem dvofazan, i da pored dominantne perovskitne faze sadrži udeo stroncijum hromata. Ugljenična pasta elektroda je modifikovana sintetisanim perovskitima kako bi se ispitala njihova elektroaktivnost. Tako dobijene elektrode su primenjene za oksido-redukciju 4-nitrofenola u kiseloj sredini. Prisustvo rutenijuma u perovskitnoj strukturi dovodi do povećane elektrohemijske aktivnosti elektrode za redukciju 4-nitrofenola.
In this paper new perovskite-based electrode materialsfor 4-nitrophenol detection were characterized. Mixed oxides of pereovskite type with general molecular formula La0.7Sr0.3Cr1-XRuX03 (X= 0; 0.05) were synthesized by ceramic procedure. The results of X-ray diffraction analysis showed that synthesized system has two-phase structure, including strontium chromate phase beside dominant perovskite phase. Carbon paste electrode was modified with synthsized perovskites in order to study their electrochemical activity. Electrode prepared innn such manner were used for oxido-reduction of 4-nitrophenol in acidic media. The addition of ruthenium to perovskite structure lead to increased electrochemical activity of this electrode for reduction of 4-nitrophenol.
Keywords:
perovskit / rutenijum / elektroda / 4-nitrofenol / perovskite / ruthenium / electrode / 4-nitrophenol
Source:
Tehnika, 2020, 29, 6, 695-699
Publisher:
  • Beograd : Savez inženjera i tehničara Srbije
Funding / projects:
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200026 (University of Belgrade, Institute of Chemistry, Technology and Metallurgy - IChTM) (RS-200026)

DOI: 10.5937/tehnika2006695M

ISSN: 0040-2176

[ Google Scholar ]
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/4086
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - JOUR
AU  - Mojović, Zorica
AU  - Petrović, Srđan
AU  - Rožić, Ljiljana
PY  - 2020
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/4086
AB  - U ovom radu su okarakterisani novi elektrodni materijali na bazi perovskita za detekciju 4-nitrofenola.
Mešoviti oksidi perovskitnog tipa hemijske formule La0.7Sr0.3Cr1-XRuXO3 (X= 0; 0.05) su sintetisani
konvencionalnim keramičkim postupkom. Rezultati rendgenske difrakcione analize su pokazali da je
sintetizovani sistem dvofazan, i da pored dominantne perovskitne faze sadrži udeo stroncijum hromata.
Ugljenična pasta elektroda je modifikovana sintetisanim perovskitima kako bi se ispitala njihova
elektroaktivnost. Tako dobijene elektrode su primenjene za oksido-redukciju 4-nitrofenola u kiseloj
sredini. Prisustvo rutenijuma u perovskitnoj strukturi dovodi do povećane elektrohemijske aktivnosti
elektrode za redukciju 4-nitrofenola.
AB  - In this paper new perovskite-based electrode materialsfor 4-nitrophenol detection were characterized. Mixed oxides of pereovskite type with general molecular formula La0.7Sr0.3Cr1-XRuX03 (X= 0; 0.05) were synthesized by ceramic procedure. The results of X-ray diffraction analysis showed that synthesized system has two-phase structure, including strontium chromate phase beside dominant perovskite phase. Carbon paste electrode was modified with synthsized perovskites in order to study their electrochemical activity. Electrode prepared innn such manner were used for oxido-reduction of 4-nitrophenol in acidic media. The addition of ruthenium to perovskite structure lead to increased electrochemical activity of this electrode for reduction of 4-nitrophenol.
PB  - Beograd : Savez inženjera i tehničara Srbije
T2  - Tehnika
T1  - Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola
T1  - The role of ruthenium in perovskite-type mixed oxide in the electrochemical degradation of 4-nitrophenol
VL  - 29
IS  - 6
SP  - 695
EP  - 699
DO  - 10.5937/tehnika2006695M
ER  - 
@article{
author = "Mojović, Zorica and Petrović, Srđan and Rožić, Ljiljana",
year = "2020",
abstract = "U ovom radu su okarakterisani novi elektrodni materijali na bazi perovskita za detekciju 4-nitrofenola.
Mešoviti oksidi perovskitnog tipa hemijske formule La0.7Sr0.3Cr1-XRuXO3 (X= 0; 0.05) su sintetisani
konvencionalnim keramičkim postupkom. Rezultati rendgenske difrakcione analize su pokazali da je
sintetizovani sistem dvofazan, i da pored dominantne perovskitne faze sadrži udeo stroncijum hromata.
Ugljenična pasta elektroda je modifikovana sintetisanim perovskitima kako bi se ispitala njihova
elektroaktivnost. Tako dobijene elektrode su primenjene za oksido-redukciju 4-nitrofenola u kiseloj
sredini. Prisustvo rutenijuma u perovskitnoj strukturi dovodi do povećane elektrohemijske aktivnosti
elektrode za redukciju 4-nitrofenola., In this paper new perovskite-based electrode materialsfor 4-nitrophenol detection were characterized. Mixed oxides of pereovskite type with general molecular formula La0.7Sr0.3Cr1-XRuX03 (X= 0; 0.05) were synthesized by ceramic procedure. The results of X-ray diffraction analysis showed that synthesized system has two-phase structure, including strontium chromate phase beside dominant perovskite phase. Carbon paste electrode was modified with synthsized perovskites in order to study their electrochemical activity. Electrode prepared innn such manner were used for oxido-reduction of 4-nitrophenol in acidic media. The addition of ruthenium to perovskite structure lead to increased electrochemical activity of this electrode for reduction of 4-nitrophenol.",
publisher = "Beograd : Savez inženjera i tehničara Srbije",
journal = "Tehnika",
title = "Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola, The role of ruthenium in perovskite-type mixed oxide in the electrochemical degradation of 4-nitrophenol",
volume = "29",
number = "6",
pages = "695-699",
doi = "10.5937/tehnika2006695M"
}
Mojović, Z., Petrović, S.,& Rožić, L.. (2020). Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola. in Tehnika
Beograd : Savez inženjera i tehničara Srbije., 29(6), 695-699.
https://doi.org/10.5937/tehnika2006695M
Mojović Z, Petrović S, Rožić L. Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola. in Tehnika. 2020;29(6):695-699.
doi:10.5937/tehnika2006695M .
Mojović, Zorica, Petrović, Srđan, Rožić, Ljiljana, "Uloga rutenijuma u mešovitom oksidu perovskitnog tipa u elektrohemijskoj degradaciji 4-nitrofenola" in Tehnika, 29, no. 6 (2020):695-699,
https://doi.org/10.5937/tehnika2006695M . .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB