Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes
Само за регистроване кориснике
1990
Чланак у часопису (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time.
Кључне речи:
article / assay / cyanide / ion selective electrode / methodology / nonhuman / silver iodide / silver sulfide / unclassified drugИзвор:
Analytica Chimica Acta, 1990, 233, C, 329-333Институција/група
IHTMTY - JOUR AU - Jovanović, Vladislava M. AU - Jovanović, Momir S. PY - 1990 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/3663 AB - It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time. T2 - Analytica Chimica Acta T1 - Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes VL - 233 IS - C SP - 329 EP - 333 DO - 10.1016/S0003-2670(00)83499-6 ER -
@article{ author = "Jovanović, Vladislava M. and Jovanović, Momir S.", year = "1990", abstract = "It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time.", journal = "Analytica Chimica Acta", title = "Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes", volume = "233", number = "C", pages = "329-333", doi = "10.1016/S0003-2670(00)83499-6" }
Jovanović, V. M.,& Jovanović, M. S.. (1990). Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes. in Analytica Chimica Acta, 233(C), 329-333. https://doi.org/10.1016/S0003-2670(00)83499-6
Jovanović VM, Jovanović MS. Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes. in Analytica Chimica Acta. 1990;233(C):329-333. doi:10.1016/S0003-2670(00)83499-6 .
Jovanović, Vladislava M., Jovanović, Momir S., "Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes" in Analytica Chimica Acta, 233, no. C (1990):329-333, https://doi.org/10.1016/S0003-2670(00)83499-6 . .