CER - Central Repository
Institute of Chemistry, Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes

Authorized Users Only
1990
Authors
Jovanović, Vladislava M.
Jovanović, Momir S.
Article (Published version)
Metadata
Show full item record
Abstract
It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time.
Keywords:
article / assay / cyanide / ion selective electrode / methodology / nonhuman / silver iodide / silver sulfide / unclassified drug
Source:
Analytica Chimica Acta, 1990, 233, C, 329-333

DOI: 10.1016/S0003-2670(00)83499-6

ISSN: 0003-2670

Scopus: 2-s2.0-0025070887
[ Google Scholar ]
6
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/3663
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - JOUR
AU  - Jovanović, Vladislava M.
AU  - Jovanović, Momir S.
PY  - 1990
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3663
AB  - It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time.
T2  - Analytica Chimica Acta
T1  - Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes
VL  - 233
IS  - C
SP  - 329
EP  - 333
DO  - 10.1016/S0003-2670(00)83499-6
ER  - 
@article{
author = "Jovanović, Vladislava M. and Jovanović, Momir S.",
year = "1990",
abstract = "It is shown that the equation for the potentials of semiconductive sulphide membranes given by Sato 25 years ago is valid also for the calculation of E0 values of "cyanide-sensitive" ion-selective electrodes. The only requirement for such an approach to the problem is information on the activities of relevant species in both the solid and the liquid phases. In this way, the E0 value given by Pungor and Toth for the silver iodide membrane in cyanide solution was confirmed, and E0 for silver sulphide in cyanide solution was evaluated for the first time.",
journal = "Analytica Chimica Acta",
title = "Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes",
volume = "233",
number = "C",
pages = "329-333",
doi = "10.1016/S0003-2670(00)83499-6"
}
Jovanović, V. M.,& Jovanović, M. S.. (1990). Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes. in Analytica Chimica Acta, 233(C), 329-333.
https://doi.org/10.1016/S0003-2670(00)83499-6
Jovanović VM, Jovanović MS. Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes. in Analytica Chimica Acta. 1990;233(C):329-333.
doi:10.1016/S0003-2670(00)83499-6 .
Jovanović, Vladislava M., Jovanović, Momir S., "Standard potential values of "cyanide-sensitive" silver iodide and silver sulphide ion-selective electrodes" in Analytica Chimica Acta, 233, no. C (1990):329-333,
https://doi.org/10.1016/S0003-2670(00)83499-6 . .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB