CER - Central Repository
Institute of Chemistry, Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water

Thumbnail
2018
bitstream_16565.pdf (2.253Mb)
Authors
Jevtić, Sonja
Vukojević, Vesna
Đurđić, Slađana
Pergal, Marija
Manojlović, Dragan
Petković, Branka B.
Stanković, Dalibor
Conference object (Published version)
Metadata
Show full item record
Abstract
Pethoxamid (POA) is relatively new herbicide and it belongs to group of chloroacetamides. It inhibits the germination of target weeds in corn, soybeans, peas and beans, tobacco and other crops and it can affects on herbicide-resistant weeds. There are no many research records about this, in the future quite applicable, herbicide. Bearing in mind that pethoxamid is high soluble in water, with almost no sorption in soils [1], the leaching and runoff of this compound in ground and surface water is a real threat. Pethoxamid residues in soil, water food and feed of plant origin usually were determined by using liquid chromatography with tandem mass spectrometry (LC–MS/MS) [2] while some other analytical methods were used for determination of pesticides [3]. The electroanalytical methods are noted as fast and cost-effective analytical methods for determination of many analytes of environmental interest. As far as we know, this is a first report about electrochemical behavior of herbicide p...ethoxamid and its electroanalytical determination. This method is based on the electrochemical oxidation of pethoxamid in Britton-Robinson buffer solution at pH 4 at a boron-doped diamond electrode. This type of carbon electrode is almost resistant to contamination of surface with various chemical spaces, easy to maintain and has a very wide working potential window which could provide insight into the electrochemical oxidation of pethoxamid at high anodic potentials. All electrochemical measurements (cyclic and square-wave voltammetry) were performed on PalmSens 3 potentiostat/galvanostat/impedance analyzer with PSTrace software (PalmSens BV, Netherlands). Three-electrode system in the electrochemical cell was consisted from Ag/AgCl (1M KCl) reference electrode and platinum wire counter electrode, while working electrode was boron-doped diamond electrode. BDD electrode was electrochemicaly prepared as it was written before [4]. Cyclic voltammetry provided a well defined oxidation peak at +1.35 V, and this peak was used as a peak of quantification at a optimal pH value 4 (Figure 1 a). The square-wave voltammetry was chosen as suitable technique for analytical determination of pethoxamid with an established optimal working conditions (pulse amplitude of 60 mV and frequency of 10 Hz). The voltammograms obtained for standard solutions from 1 to 100 μM and corresponding calibration curve were shown on Figure 1 b. The method was applied for selective quantification of pethoxamid from spiked river water samples with good recovery of 92.0 to 104.6% for standard solutions of POA and good agreement with comparative HPLC method (97.6-98.1%). The results of this research indicate successful, fast, simple, reliable and cheap estimation of pethoxamid content in the surface water samples with no electrode surface modification and time-consuming sample preparation.

Source:
8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia, 2018, 111-112
Publisher:
  • Srpsko hemijsko društvo, Karnegijeva 4/III, Beograd, Srbija / Serbian Chemical Society, Karnegijeva 4/III, Belgrade, Serbia

ISBN: 978-86-7132-068-9

[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_cer_3559
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/3559
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - CONF
AU  - Jevtić, Sonja
AU  - Vukojević, Vesna
AU  - Đurđić, Slađana
AU  - Pergal, Marija
AU  - Manojlović, Dragan
AU  - Petković, Branka B.
AU  - Stanković, Dalibor
PY  - 2018
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3559
AB  - Pethoxamid (POA) is relatively new herbicide and it belongs to group of chloroacetamides. It inhibits the germination of target weeds in corn, soybeans, peas and beans, tobacco and other crops and it can affects on herbicide-resistant weeds. There are no many research records about this, in the future quite applicable, herbicide. Bearing in mind that pethoxamid is high soluble in water, with almost no sorption in soils [1], the leaching and runoff of this compound in ground and surface water is a real threat. Pethoxamid residues in soil, water food and feed of plant origin usually were determined by using liquid chromatography with tandem mass spectrometry (LC–MS/MS) [2] while some other analytical methods were used for determination of pesticides [3].
 The electroanalytical methods are noted as fast and cost-effective analytical methods for determination of many analytes of environmental interest. As far as we know, this is a first report about electrochemical behavior of herbicide pethoxamid and its electroanalytical determination. This method is based on the electrochemical oxidation of pethoxamid in Britton-Robinson buffer solution at pH 4 at a boron-doped diamond electrode. This type of carbon electrode is almost resistant to contamination of surface with various chemical spaces, easy to maintain and has a very wide working potential window which could provide insight into the electrochemical oxidation of pethoxamid at high anodic potentials. All electrochemical measurements (cyclic and square-wave voltammetry) were performed on PalmSens 3 potentiostat/galvanostat/impedance analyzer with PSTrace software (PalmSens BV, Netherlands). Three-electrode system in the electrochemical cell was consisted from Ag/AgCl (1M KCl) reference electrode and platinum wire counter electrode, while working electrode was boron-doped diamond electrode. BDD electrode
 was electrochemicaly prepared as it was written before [4]. Cyclic voltammetry provided a well defined oxidation peak at +1.35 V, and this peak was used as a peak of quantification at a optimal pH value 4 (Figure 1 a). The square-wave voltammetry was chosen as suitable technique for analytical determination of pethoxamid with an established optimal working conditions (pulse amplitude of 60 mV and frequency of 10 Hz). The voltammograms obtained for standard solutions from 1 to 100 μM and corresponding calibration curve were shown on Figure 1 b. The method was applied for selective quantification of pethoxamid from spiked river water samples with good recovery of 92.0 to 104.6% for standard solutions of POA and good agreement with comparative HPLC method (97.6-98.1%). The results of this research indicate successful, fast, simple, reliable and cheap estimation of pethoxamid content in the surface water samples with no electrode surface modification and time-consuming sample preparation.
PB  - Srpsko hemijsko društvo, Karnegijeva 4/III, Beograd, Srbija / Serbian Chemical Society, Karnegijeva 4/III, Belgrade, Serbia
C3  - 8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia
T1  - First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water
SP  - 111
EP  - 112
UR  - https://hdl.handle.net/21.15107/rcub_cer_3559
ER  - 
@conference{
author = "Jevtić, Sonja and Vukojević, Vesna and Đurđić, Slađana and Pergal, Marija and Manojlović, Dragan and Petković, Branka B. and Stanković, Dalibor",
year = "2018",
abstract = "Pethoxamid (POA) is relatively new herbicide and it belongs to group of chloroacetamides. It inhibits the germination of target weeds in corn, soybeans, peas and beans, tobacco and other crops and it can affects on herbicide-resistant weeds. There are no many research records about this, in the future quite applicable, herbicide. Bearing in mind that pethoxamid is high soluble in water, with almost no sorption in soils [1], the leaching and runoff of this compound in ground and surface water is a real threat. Pethoxamid residues in soil, water food and feed of plant origin usually were determined by using liquid chromatography with tandem mass spectrometry (LC–MS/MS) [2] while some other analytical methods were used for determination of pesticides [3].
 The electroanalytical methods are noted as fast and cost-effective analytical methods for determination of many analytes of environmental interest. As far as we know, this is a first report about electrochemical behavior of herbicide pethoxamid and its electroanalytical determination. This method is based on the electrochemical oxidation of pethoxamid in Britton-Robinson buffer solution at pH 4 at a boron-doped diamond electrode. This type of carbon electrode is almost resistant to contamination of surface with various chemical spaces, easy to maintain and has a very wide working potential window which could provide insight into the electrochemical oxidation of pethoxamid at high anodic potentials. All electrochemical measurements (cyclic and square-wave voltammetry) were performed on PalmSens 3 potentiostat/galvanostat/impedance analyzer with PSTrace software (PalmSens BV, Netherlands). Three-electrode system in the electrochemical cell was consisted from Ag/AgCl (1M KCl) reference electrode and platinum wire counter electrode, while working electrode was boron-doped diamond electrode. BDD electrode
 was electrochemicaly prepared as it was written before [4]. Cyclic voltammetry provided a well defined oxidation peak at +1.35 V, and this peak was used as a peak of quantification at a optimal pH value 4 (Figure 1 a). The square-wave voltammetry was chosen as suitable technique for analytical determination of pethoxamid with an established optimal working conditions (pulse amplitude of 60 mV and frequency of 10 Hz). The voltammograms obtained for standard solutions from 1 to 100 μM and corresponding calibration curve were shown on Figure 1 b. The method was applied for selective quantification of pethoxamid from spiked river water samples with good recovery of 92.0 to 104.6% for standard solutions of POA and good agreement with comparative HPLC method (97.6-98.1%). The results of this research indicate successful, fast, simple, reliable and cheap estimation of pethoxamid content in the surface water samples with no electrode surface modification and time-consuming sample preparation.",
publisher = "Srpsko hemijsko društvo, Karnegijeva 4/III, Beograd, Srbija / Serbian Chemical Society, Karnegijeva 4/III, Belgrade, Serbia",
journal = "8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia",
title = "First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water",
pages = "111-112",
url = "https://hdl.handle.net/21.15107/rcub_cer_3559"
}
Jevtić, S., Vukojević, V., Đurđić, S., Pergal, M., Manojlović, D., Petković, B. B.,& Stanković, D.. (2018). First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water. in 8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia
Srpsko hemijsko društvo, Karnegijeva 4/III, Beograd, Srbija / Serbian Chemical Society, Karnegijeva 4/III, Belgrade, Serbia., 111-112.
https://hdl.handle.net/21.15107/rcub_cer_3559
Jevtić S, Vukojević V, Đurđić S, Pergal M, Manojlović D, Petković BB, Stanković D. First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water. in 8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia. 2018;:111-112.
https://hdl.handle.net/21.15107/rcub_cer_3559 .
Jevtić, Sonja, Vukojević, Vesna, Đurđić, Slađana, Pergal, Marija, Manojlović, Dragan, Petković, Branka B., Stanković, Dalibor, "First study of electrochemical behavior of herbicide pethoxamid and its voltammetric determination in river water" in 8. Simpozijum Hemija i zaštita životne sredine (sa međunarodnim učešćem) / 8th Symposium Chemistry and Environmental Protection (with international participation), 30.5-01.06.2018., Kruševac, Serbia (2018):111-112,
https://hdl.handle.net/21.15107/rcub_cer_3559 .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB