Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom

Electrochemical detection of antimony on electrodes based on poly(vinyl alcohol)/clay composites

Thumbnail
2019
0040-21761906771M.pdf (460.1Kb)
Authors
Marinović, Sanja
Mudrinić, Tihana
Milutinović Nikolić, Aleksandra
Mojović, Zorica
Article (Published version)
Metadata
Show full item record
Abstract
Sintetisani su kompoziti gline i poli(vinil alkohola) (PVA) sa masenim odnosima PVA/glina 10% i 20%. Kompoziti su naneti na površinu disk elektrode od staklastog ugljenika pomoću Nafiona. Tako modifikovane elektrode su korišćene za detekciju antimona. Poređenjem sa ponašanjem nemodifikovanih glina praćen je uticaj PVA na osetljivost elektroda za detekciju antimona. Dorpinos Nafiona je određen testiranjem elektrode koja je prekrivena samo Nafionom. Osetljivost modifikovane elektrode za detekciju antimona je povećana formiranjem poli(pirogalolnog) filma na površini elektrode. Elektroda je pokazala dobru reproduktivnost i limit detekcije od 0,2 µM. Prisustvo Cu(II) katjona u koncentracijama većim od 1µM je značajno ometalo detekciju antimona na isptivanoj elektrodi.
Composites of clay and poly(vinyl alcohol) (PVA) were synthesized using different PVA loadings (10 wt.% and 20 wt.%). Glassy carbon electrode (GCE) was modified with the obtained samples using Nafion. Modified electrodes were used for the analytical detection of antimony. The influence of PVA on electrode sensitivity toward antimony was determined by comparison with the behavior of GCE modified with pure clay. The contribution of Nafion was assessed by testing GCE covered only with Nafion. The sensitivity of PVA/clay modified GCE for antimony was further enhanced by formation of poly- (pyrogallol) film on electrode surface by electropolymerization. Electrode showed good repeatability and detection limit of 0.2 µM. The presence of Cu(II) in concentrations higher than 1 µM in Sb(III) solution interfered with electrode response towards Sb(III)
Keywords:
antimon / PVA/glina / modifikovana elektroda / poli(pirogalol) / antimony / PVA/clay / modified electrode / poly(pyrogallol)
Source:
Tehnika, 2019, 74, 6, 771-776
Publisher:
  • Beograd : Savez inženjera i tehničara Srbije
Funding / projects:
  • Nanostructured Functional and Composite Materials in Catalytic and Sorption Processes (RS-45001)

DOI: 10.5937/tehnika1906771M

ISSN: 0040-2176; 2560-3086

[ Google Scholar ]
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/3454
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - JOUR
AU  - Marinović, Sanja
AU  - Mudrinić, Tihana
AU  - Milutinović Nikolić, Aleksandra
AU  - Mojović, Zorica
PY  - 2019
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3454
AB  - Sintetisani su kompoziti gline i poli(vinil alkohola) (PVA) sa masenim odnosima PVA/glina 10% i 20%. Kompoziti su naneti na površinu disk elektrode od staklastog ugljenika pomoću Nafiona. Tako modifikovane elektrode su korišćene za detekciju antimona. Poređenjem sa ponašanjem nemodifikovanih glina praćen je uticaj PVA na osetljivost elektroda za detekciju antimona. Dorpinos Nafiona je određen testiranjem elektrode koja je prekrivena samo Nafionom. Osetljivost modifikovane elektrode za detekciju antimona je povećana formiranjem poli(pirogalolnog) filma na površini elektrode. Elektroda je pokazala dobru reproduktivnost i limit detekcije od 0,2 µM. Prisustvo Cu(II) katjona u koncentracijama većim od 1µM je značajno ometalo detekciju antimona na isptivanoj elektrodi.
AB  - Composites of clay and poly(vinyl alcohol) (PVA) were synthesized using different PVA loadings (10
wt.% and 20 wt.%). Glassy carbon electrode (GCE) was modified with the obtained samples using
Nafion. Modified electrodes were used for the analytical detection of antimony. The influence of PVA on
electrode sensitivity toward antimony was determined by comparison with the behavior of GCE modified
with pure clay. The contribution of Nafion was assessed by testing GCE covered only with Nafion. The
sensitivity of PVA/clay modified GCE for antimony was further enhanced by formation of poly-
(pyrogallol) film on electrode surface by electropolymerization. Electrode showed good repeatability
and detection limit of 0.2 µM. The presence of Cu(II) in concentrations higher than 1 µM in Sb(III)
solution interfered with electrode response towards Sb(III)
PB  - Beograd : Savez inženjera i tehničara Srbije
T2  - Tehnika
T1  - Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom
T1  - Electrochemical detection of antimony on electrodes based on poly(vinyl alcohol)/clay composites
VL  - 74
IS  - 6
SP  - 771
EP  - 776
DO  - 10.5937/tehnika1906771M
ER  - 
@article{
author = "Marinović, Sanja and Mudrinić, Tihana and Milutinović Nikolić, Aleksandra and Mojović, Zorica",
year = "2019",
abstract = "Sintetisani su kompoziti gline i poli(vinil alkohola) (PVA) sa masenim odnosima PVA/glina 10% i 20%. Kompoziti su naneti na površinu disk elektrode od staklastog ugljenika pomoću Nafiona. Tako modifikovane elektrode su korišćene za detekciju antimona. Poređenjem sa ponašanjem nemodifikovanih glina praćen je uticaj PVA na osetljivost elektroda za detekciju antimona. Dorpinos Nafiona je određen testiranjem elektrode koja je prekrivena samo Nafionom. Osetljivost modifikovane elektrode za detekciju antimona je povećana formiranjem poli(pirogalolnog) filma na površini elektrode. Elektroda je pokazala dobru reproduktivnost i limit detekcije od 0,2 µM. Prisustvo Cu(II) katjona u koncentracijama većim od 1µM je značajno ometalo detekciju antimona na isptivanoj elektrodi., Composites of clay and poly(vinyl alcohol) (PVA) were synthesized using different PVA loadings (10
wt.% and 20 wt.%). Glassy carbon electrode (GCE) was modified with the obtained samples using
Nafion. Modified electrodes were used for the analytical detection of antimony. The influence of PVA on
electrode sensitivity toward antimony was determined by comparison with the behavior of GCE modified
with pure clay. The contribution of Nafion was assessed by testing GCE covered only with Nafion. The
sensitivity of PVA/clay modified GCE for antimony was further enhanced by formation of poly-
(pyrogallol) film on electrode surface by electropolymerization. Electrode showed good repeatability
and detection limit of 0.2 µM. The presence of Cu(II) in concentrations higher than 1 µM in Sb(III)
solution interfered with electrode response towards Sb(III)",
publisher = "Beograd : Savez inženjera i tehničara Srbije",
journal = "Tehnika",
title = "Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom, Electrochemical detection of antimony on electrodes based on poly(vinyl alcohol)/clay composites",
volume = "74",
number = "6",
pages = "771-776",
doi = "10.5937/tehnika1906771M"
}
Marinović, S., Mudrinić, T., Milutinović Nikolić, A.,& Mojović, Z.. (2019). Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom. in Tehnika
Beograd : Savez inženjera i tehničara Srbije., 74(6), 771-776.
https://doi.org/10.5937/tehnika1906771M
Marinović S, Mudrinić T, Milutinović Nikolić A, Mojović Z. Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom. in Tehnika. 2019;74(6):771-776.
doi:10.5937/tehnika1906771M .
Marinović, Sanja, Mudrinić, Tihana, Milutinović Nikolić, Aleksandra, Mojović, Zorica, "Elektrohemijsko određivanje antimona na elektrodama sa poli(vinil alkohol)/glina kompozitom" in Tehnika, 74, no. 6 (2019):771-776,
https://doi.org/10.5937/tehnika1906771M . .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB