Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors

Thumbnail
2019
Jokic_IcETRAN-2019.pdf (1.394Mb)
Authors
Jokić, Ivana
Radulović, Katarina
Frantlović, Miloš
Đurić, Zoran G.
Cvetanović Zobenica, Katarina
Krstajić, Predrag
Conference object (Published version)
Metadata
Show full item record
Abstract
Detection limits in microfluidic chemical and biological sensors, which determine the range of analyte concentrations reliably detectable by the sensor, are important sensor parameters. The lower limit of detection, defined as the lowest concentration that can be distinguished from noise, has its minimum determined by the fundamental adsorption-desorption (AD) noise, inevitable in adsorption-based devices. In this work, we analyze this fundamental detection limit, particularly considering the influence of mass transfer processes in microfluidic devices. For that purpose, we derive the expression for the sensor’s signal-to-noise ratio (SNR), which takes into account the AD noise, and then the equation for the minimal analyte concentration at which the SNR has a sufficiently high value for reliable analyte detection. Subsequently, we analyze the mass transfer influence on the sensor’s maximal achievable signal-to-noise ratio and on the fundamental detection limit. The results of the anal...ysis show a significant mass transfer influence on these important sensor performance metrics. They also provide guidelines for achieving the sensor’s best possible detection performance through the optimization of the sensor design and operating conditions.

Keywords:
microfluidic sensors / biosensors / chemical sensors / detection limit / mass transfer / signal-to-noise ratio
Source:
Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine, 2019, 571-574
Publisher:
  • Belgrade : ETRAN
  • Belgrade :Academic Mind
Funding / projects:
  • Micro- Nanosystems and Sensors for Electric Power and Process Industry and Environmental Protection (RS-32008)
  • Serbian Academy of Sciences and Arts, Project F-150

ISBN: 978-86-7466-785-9

[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_dais_6961
URI
http://dais.sanu.ac.rs/123456789/6961
https://cer.ihtm.bg.ac.rs/handle/123456789/3326
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - CONF
AU  - Jokić, Ivana
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Đurić, Zoran G.
AU  - Cvetanović Zobenica, Katarina
AU  - Krstajić, Predrag
PY  - 2019
UR  - http://dais.sanu.ac.rs/123456789/6961
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3326
AB  - Detection limits in microfluidic chemical and biological sensors, which determine the range of analyte concentrations reliably detectable by the sensor, are important sensor parameters. The lower limit of detection, defined as the lowest concentration that can be distinguished from noise, has its minimum determined by the fundamental adsorption-desorption (AD) noise, inevitable in adsorption-based devices. In this work, we analyze this fundamental detection limit, particularly considering the influence of mass transfer processes in microfluidic devices. For that purpose, we derive the expression for the sensor’s signal-to-noise ratio (SNR), which takes into account the AD noise, and then the equation for the minimal analyte concentration at which the SNR has a sufficiently high value for reliable analyte detection. Subsequently, we analyze the mass transfer influence on the sensor’s maximal achievable signal-to-noise ratio and on the fundamental detection limit. The results of the analysis show a significant mass transfer influence on these important sensor performance metrics. They also provide guidelines for achieving the sensor’s best possible detection performance through the optimization of the sensor design and operating conditions.
PB  - Belgrade : ETRAN
PB  - Belgrade :Academic Mind
C3  - Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine
T1  - Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors
SP  - 571
EP  - 574
UR  - https://hdl.handle.net/21.15107/rcub_dais_6961
ER  - 
@conference{
author = "Jokić, Ivana and Radulović, Katarina and Frantlović, Miloš and Đurić, Zoran G. and Cvetanović Zobenica, Katarina and Krstajić, Predrag",
year = "2019",
abstract = "Detection limits in microfluidic chemical and biological sensors, which determine the range of analyte concentrations reliably detectable by the sensor, are important sensor parameters. The lower limit of detection, defined as the lowest concentration that can be distinguished from noise, has its minimum determined by the fundamental adsorption-desorption (AD) noise, inevitable in adsorption-based devices. In this work, we analyze this fundamental detection limit, particularly considering the influence of mass transfer processes in microfluidic devices. For that purpose, we derive the expression for the sensor’s signal-to-noise ratio (SNR), which takes into account the AD noise, and then the equation for the minimal analyte concentration at which the SNR has a sufficiently high value for reliable analyte detection. Subsequently, we analyze the mass transfer influence on the sensor’s maximal achievable signal-to-noise ratio and on the fundamental detection limit. The results of the analysis show a significant mass transfer influence on these important sensor performance metrics. They also provide guidelines for achieving the sensor’s best possible detection performance through the optimization of the sensor design and operating conditions.",
publisher = "Belgrade : ETRAN, Belgrade :Academic Mind",
journal = "Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine",
title = "Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors",
pages = "571-574",
url = "https://hdl.handle.net/21.15107/rcub_dais_6961"
}
Jokić, I., Radulović, K., Frantlović, M., Đurić, Z. G., Cvetanović Zobenica, K.,& Krstajić, P.. (2019). Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors. in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine
Belgrade : ETRAN., 571-574.
https://hdl.handle.net/21.15107/rcub_dais_6961
Jokić I, Radulović K, Frantlović M, Đurić ZG, Cvetanović Zobenica K, Krstajić P. Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors. in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine. 2019;:571-574.
https://hdl.handle.net/21.15107/rcub_dais_6961 .
Jokić, Ivana, Radulović, Katarina, Frantlović, Miloš, Đurić, Zoran G., Cvetanović Zobenica, Katarina, Krstajić, Predrag, "Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors" in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine (2019):571-574,
https://hdl.handle.net/21.15107/rcub_dais_6961 .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB