Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube
Samo za registrovane korisnike
1977
Članak u časopisu (Objavljena verzija)

Elsevier BV
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
As a continuation of earlier work on arc sources for the spectrochemical analysis of powdered samples, a source appropriate for multi-element analysis of trace elements in solution has been developed. The nebulized solution to be analysed is introduced into a horizontal graphite tube in the gap between two plasmas rotating in a magnetic field. Both water and ethanol have been used as solvents and the effect of lithium additions on the detection limits for certain elements has been studied. This source provides advantageous conditions for the determination of trace elements present at very low concentrations. Source parameters investigated include a study of the magnetically induced rotation of the plasmas by high speed cine photography, and the temperature distribution within the tube. Both aqueous and ethanol solutions were used and the effect of lithium additions was measured.
Izvor:
Spectrochimica Acta Part B: Atomic Spectroscopy, 1977, 32, 11-12, 445-454Izdavač:
- Elsevier
Institucija/grupa
IHTMTY - JOUR AU - Vukanović, D. AU - Simić, M. AU - Kovačić, N. AU - Vukanović, V. AU - Nickel, H. AU - Mazurkiewicz, M. PY - 1977 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/2980 AB - As a continuation of earlier work on arc sources for the spectrochemical analysis of powdered samples, a source appropriate for multi-element analysis of trace elements in solution has been developed. The nebulized solution to be analysed is introduced into a horizontal graphite tube in the gap between two plasmas rotating in a magnetic field. Both water and ethanol have been used as solvents and the effect of lithium additions on the detection limits for certain elements has been studied. This source provides advantageous conditions for the determination of trace elements present at very low concentrations. Source parameters investigated include a study of the magnetically induced rotation of the plasmas by high speed cine photography, and the temperature distribution within the tube. Both aqueous and ethanol solutions were used and the effect of lithium additions was measured. PB - Elsevier T2 - Spectrochimica Acta Part B: Atomic Spectroscopy T1 - Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube VL - 32 IS - 11-12 SP - 445 EP - 454 DO - 10.1016/0584-8547(77)80018-9 ER -
@article{ author = "Vukanović, D. and Simić, M. and Kovačić, N. and Vukanović, V. and Nickel, H. and Mazurkiewicz, M.", year = "1977", abstract = "As a continuation of earlier work on arc sources for the spectrochemical analysis of powdered samples, a source appropriate for multi-element analysis of trace elements in solution has been developed. The nebulized solution to be analysed is introduced into a horizontal graphite tube in the gap between two plasmas rotating in a magnetic field. Both water and ethanol have been used as solvents and the effect of lithium additions on the detection limits for certain elements has been studied. This source provides advantageous conditions for the determination of trace elements present at very low concentrations. Source parameters investigated include a study of the magnetically induced rotation of the plasmas by high speed cine photography, and the temperature distribution within the tube. Both aqueous and ethanol solutions were used and the effect of lithium additions was measured.", publisher = "Elsevier", journal = "Spectrochimica Acta Part B: Atomic Spectroscopy", title = "Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube", volume = "32", number = "11-12", pages = "445-454", doi = "10.1016/0584-8547(77)80018-9" }
Vukanović, D., Simić, M., Kovačić, N., Vukanović, V., Nickel, H.,& Mazurkiewicz, M.. (1977). Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube. in Spectrochimica Acta Part B: Atomic Spectroscopy Elsevier., 32(11-12), 445-454. https://doi.org/10.1016/0584-8547(77)80018-9
Vukanović D, Simić M, Kovačić N, Vukanović V, Nickel H, Mazurkiewicz M. Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube. in Spectrochimica Acta Part B: Atomic Spectroscopy. 1977;32(11-12):445-454. doi:10.1016/0584-8547(77)80018-9 .
Vukanović, D., Simić, M., Kovačić, N., Vukanović, V., Nickel, H., Mazurkiewicz, M., "Direct solution analysis using an arc source incorporating two plasmas rotating in a graphite tube" in Spectrochimica Acta Part B: Atomic Spectroscopy, 32, no. 11-12 (1977):445-454, https://doi.org/10.1016/0584-8547(77)80018-9 . .