dc.description.abstractBentazone (BZ) is selective contact-past herbicide with suspected reproductive toxicity potential for human due to possible contamination of ground and surface waters. This work presents simple, rapid, sensitive and accurate determination of bentazone at unmodified boron-doped diamond electrode, using differential pulse voltammetry in Britton-Robinson buffer (pH 4, oxidation peak at 1.0 V). Under optimized DPV conditions linear calibration curve was obtained for range of 2 to 100 mu M, with a detection limit of 0.5 mu M. The effect of possible interfering agents is negligible, confirming good selectivity of the method. The method was successfully applied to determination of bentazone in spiked river water samples. This electrochemical determination of bentazone represents a favorable alternative to other used time-consuming and expensive analytical techniques and procedures.en
dc.publisherElsevier Science Sa, Lausanne
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/45022/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172030/RS//
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/621375/EU//
dc.rightsembargoedAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceDiamond and Related Materials
dc.subjectBentazone determinationen
dc.subjectElectrochemical methoden
dc.subjectVoltanunetryen
dc.subjectRiver water samplesen
dc.titleBoron-doped diamond electrode - A prestigious unmodified carbon electrode for simple and fast determination of bentazone in river water samplesen
dc.typearticle
dc.rights.licenseBY-NC-ND
dcterms.abstractПетковиц, Бранка Б.; Ивановиц, Aлександра Т.; Пергал, Марија; Јевтиц, Соња; Стефановиц, Aндела; Јокиц, Aња; Станковиц, Далибор М.;
dc.citation.volume81
dc.citation.spage133
dc.citation.epage137
dc.citation.other81: 133-137
dc.citation.rankM22
dc.description.other[http://cer.ihtm.bg.ac.rs/handle/123456789/2470]
dc.description.otherThis is peer-reviewed version of the following article: Jevtić, S.; Stefanović, A.; Stanković, D. M.; Pergal, M. V.; Ivanović, A. T.; Jokić, A.; Petković, B. B. Boron-Doped Diamond Electrode — A Prestigious Unmodified Carbon Electrode for Simple and Fast Determination of Bentazone in River Water Samples. Diamond and Related Materials 2018, 81, 133–137, [https://doi.org/10.1016/j.diamond.2017.12.009]
dc.identifier.doi10.1016/j.diamond.2017.12.009
dc.identifier.fulltexthttps://cer.ihtm.bg.ac.rs/bitstream/id/7273/1_2906_j.diamond.2017.12.009.pdf
dc.identifier.scopus2-s2.0-85037548233
dc.identifier.wos000424310600018
dc.type.versionacceptedVersion


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record