CER - Centralni Repozitorijum IHTM-a
Institut za hemiju, tehnologiju i metalurgiju
    • English
    • Српски
    • Српски (Serbia)
  • Srpski (latinica) 
    • Engleski
    • Srpski (ćirilica)
    • Srpski (latinica)
  • Prijava
Pregled zapisa 
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • Pregled zapisa
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • Pregled zapisa
JavaScript is disabled for your browser. Some features of this site may not work without it.

GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods

Thumbnail
2017
2096.pdf (2.268Mb)
Autori
Faraj, Musbah Abduljalil M.
Šolević Knudsen, Tatjana
Stojanović, Ksenija
Pavlovic, Sonja Ivkovic
Nytoft, Hans Peter
Jovančićević, Branimir
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
The values of parameters calculated from distribution and abundance of the selected pentacyclic terpanes in crude oils from Libya and Serbia, which were originally derived from gas chromatography-mass spectrometry (GC-MS) were compared with results of quantification based on gas chromatography-mass spectrometry-mass spectrometry (GC-MS-MS). The parameters analyzed are the most often used terpane source and maturity parameters, which were applied to a large sample set of 70 oils, originating from five oil fields. The aim of the paper was to investigate to which extent the measurements of the selected parameters by these two instrumental techniques agree and to determine the influence of differences between parameter values on geochemical interpretation. For that purpose two methods, concordance correlation coefficient and mean-difference plot were used. The obtained results indicate that calculation of C(27)18 alpha(H)-22,29,30-trisnorneohopane/(C(27)18 alpha(H)-22,29,30-trisnorneohopan...e +C(27)17 alpha(H)-22,29,30-trisnorhopane), C(29)18 alpha(H)-30-norneohopane/C(29)17 alpha(H) 21 beta(H)-30-norhopane and C(29)17 alpha(H)21 beta(H)-30-norhopane/ C(30)17 alpha(H)21 beta(H)-hopane ratios either by GC-MS or GC-MS-MS do not significantly influence interpretation. On the other hand, the determination of C(30)17 beta(H)21 alpha(H)-moretane/C(30)17 alpha(H)21 beta(H)-hopane ratio, gammacerane index and oleanane index by GC-MS vs. GC-MS-MS could notably affect interpretation. These differences can be explained by the co-elution and the peak overlapping in GC-MS but also by better separation, higher precision and better selectivity of the GC-MS-MS. Deviation of the almost all studied parameters from the line of equality was similar for the oils from the same oil field but some differences were observed for the oils from different oil fields. Therefore, when GC-MS-MS results are to be used in organic geochemical interpretations, a regional calibration of GC-MS vs. GC-MS-MS relationship for each petroleum system is highly recommended.

Ključne reči:
oils / terpanes / GC-MS / GC-MS-MS / concordance correlation coefficient / mean-difference plot
Izvor:
Journal of the Serbian Chemical Society, 2017, 82, 11, 1315-1331
Izdavač:
  • Serbian Chemical Soc, Belgrade
Finansiranje / projekti:
  • Geohemijska ispitivanja sedimentnih stena - fosilna goriva i zagađivači životne sredine (RS-176006)
  • Organisation for the Prohibition of Chemical Weapons (OPCW)

DOI: 10.2298/JSC170419075A

ISSN: 0352-5139

WoS: 000417845500009

Scopus: 2-s2.0-85037610284
[ Google Scholar ]
4
4
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/2098
Kolekcije
  • Radovi istraživača / Researchers' publications
Institucija/grupa
IHTM
TY  - JOUR
AU  - Faraj, Musbah Abduljalil M.
AU  - Šolević Knudsen, Tatjana
AU  - Stojanović, Ksenija
AU  - Pavlovic, Sonja Ivkovic
AU  - Nytoft, Hans Peter
AU  - Jovančićević, Branimir
PY  - 2017
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/2098
AB  - The values of parameters calculated from distribution and abundance of the selected pentacyclic terpanes in crude oils from Libya and Serbia, which were originally derived from gas chromatography-mass spectrometry (GC-MS) were compared with results of quantification based on gas chromatography-mass spectrometry-mass spectrometry (GC-MS-MS). The parameters analyzed are the most often used terpane source and maturity parameters, which were applied to a large sample set of 70 oils, originating from five oil fields. The aim of the paper was to investigate to which extent the measurements of the selected parameters by these two instrumental techniques agree and to determine the influence of differences between parameter values on geochemical interpretation. For that purpose two methods, concordance correlation coefficient and mean-difference plot were used. The obtained results indicate that calculation of C(27)18 alpha(H)-22,29,30-trisnorneohopane/(C(27)18 alpha(H)-22,29,30-trisnorneohopane +C(27)17 alpha(H)-22,29,30-trisnorhopane), C(29)18 alpha(H)-30-norneohopane/C(29)17 alpha(H) 21 beta(H)-30-norhopane and C(29)17 alpha(H)21 beta(H)-30-norhopane/ C(30)17 alpha(H)21 beta(H)-hopane ratios either by GC-MS or GC-MS-MS do not significantly influence interpretation. On the other hand, the determination of C(30)17 beta(H)21 alpha(H)-moretane/C(30)17 alpha(H)21 beta(H)-hopane ratio, gammacerane index and oleanane index by GC-MS vs. GC-MS-MS could notably affect interpretation. These differences can be explained by the co-elution and the peak overlapping in GC-MS but also by better separation, higher precision and better selectivity of the GC-MS-MS. Deviation of the almost all studied parameters from the line of equality was similar for the oils from the same oil field but some differences were observed for the oils from different oil fields. Therefore, when GC-MS-MS results are to be used in organic geochemical interpretations, a regional calibration of GC-MS vs. GC-MS-MS relationship for each petroleum system is highly recommended.
PB  - Serbian Chemical Soc, Belgrade
T2  - Journal of the Serbian Chemical Society
T1  - GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods
VL  - 82
IS  - 11
SP  - 1315
EP  - 1331
DO  - 10.2298/JSC170419075A
UR  - Conv_3841
ER  - 
@article{
author = "Faraj, Musbah Abduljalil M. and Šolević Knudsen, Tatjana and Stojanović, Ksenija and Pavlovic, Sonja Ivkovic and Nytoft, Hans Peter and Jovančićević, Branimir",
year = "2017",
abstract = "The values of parameters calculated from distribution and abundance of the selected pentacyclic terpanes in crude oils from Libya and Serbia, which were originally derived from gas chromatography-mass spectrometry (GC-MS) were compared with results of quantification based on gas chromatography-mass spectrometry-mass spectrometry (GC-MS-MS). The parameters analyzed are the most often used terpane source and maturity parameters, which were applied to a large sample set of 70 oils, originating from five oil fields. The aim of the paper was to investigate to which extent the measurements of the selected parameters by these two instrumental techniques agree and to determine the influence of differences between parameter values on geochemical interpretation. For that purpose two methods, concordance correlation coefficient and mean-difference plot were used. The obtained results indicate that calculation of C(27)18 alpha(H)-22,29,30-trisnorneohopane/(C(27)18 alpha(H)-22,29,30-trisnorneohopane +C(27)17 alpha(H)-22,29,30-trisnorhopane), C(29)18 alpha(H)-30-norneohopane/C(29)17 alpha(H) 21 beta(H)-30-norhopane and C(29)17 alpha(H)21 beta(H)-30-norhopane/ C(30)17 alpha(H)21 beta(H)-hopane ratios either by GC-MS or GC-MS-MS do not significantly influence interpretation. On the other hand, the determination of C(30)17 beta(H)21 alpha(H)-moretane/C(30)17 alpha(H)21 beta(H)-hopane ratio, gammacerane index and oleanane index by GC-MS vs. GC-MS-MS could notably affect interpretation. These differences can be explained by the co-elution and the peak overlapping in GC-MS but also by better separation, higher precision and better selectivity of the GC-MS-MS. Deviation of the almost all studied parameters from the line of equality was similar for the oils from the same oil field but some differences were observed for the oils from different oil fields. Therefore, when GC-MS-MS results are to be used in organic geochemical interpretations, a regional calibration of GC-MS vs. GC-MS-MS relationship for each petroleum system is highly recommended.",
publisher = "Serbian Chemical Soc, Belgrade",
journal = "Journal of the Serbian Chemical Society",
title = "GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods",
volume = "82",
number = "11",
pages = "1315-1331",
doi = "10.2298/JSC170419075A",
url = "Conv_3841"
}
Faraj, M. A. M., Šolević Knudsen, T., Stojanović, K., Pavlovic, S. I., Nytoft, H. P.,& Jovančićević, B.. (2017). GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods. in Journal of the Serbian Chemical Society
Serbian Chemical Soc, Belgrade., 82(11), 1315-1331.
https://doi.org/10.2298/JSC170419075A
Conv_3841
Faraj MAM, Šolević Knudsen T, Stojanović K, Pavlovic SI, Nytoft HP, Jovančićević B. GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods. in Journal of the Serbian Chemical Society. 2017;82(11):1315-1331.
doi:10.2298/JSC170419075A
Conv_3841 .
Faraj, Musbah Abduljalil M., Šolević Knudsen, Tatjana, Stojanović, Ksenija, Pavlovic, Sonja Ivkovic, Nytoft, Hans Peter, Jovančićević, Branimir, "GC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methods" in Journal of the Serbian Chemical Society, 82, no. 11 (2017):1315-1331,
https://doi.org/10.2298/JSC170419075A .,
Conv_3841 .

DSpace software copyright © 2002-2015  DuraSpace
O Centralnom repozitorijumu (CeR) | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumInstitucije/grupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O Centralnom repozitorijumu (CeR) | Pošaljite zapažanja

re3dataOpenAIRERCUB