The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process
Apstrakt
The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1 LT j(0)/j(L) LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1 LT j(0)/j(L) LT = 1. For j(0)/j(L) LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process.
Ključne reči:
lead / zinc / copper / simulation / morphology / scanning electron microscopyIzvor:
Journal of the Serbian Chemical Society, 2016, 81, 3, 291-306Izdavač:
- Serbian Chemical Society
Finansiranje / projekti:
DOI: 10.2298/JSC150717076P
ISSN: 0352-5139
WoS: 000375398500007
Scopus: 2-s2.0-84971520492
Institucija/grupa
IHTMTY - JOUR AU - Popov, Konstantin I. AU - Živković, Predrag M. AU - Jokić, Bojan AU - Nikolić, Nebojša D. PY - 2016 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/2006 AB - The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1 LT j(0)/j(L) LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1 LT j(0)/j(L) LT = 1. For j(0)/j(L) LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process. PB - Serbian Chemical Society T2 - Journal of the Serbian Chemical Society T1 - The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process VL - 81 IS - 3 SP - 291 EP - 306 DO - 10.2298/JSC150717076P ER -
@article{ author = "Popov, Konstantin I. and Živković, Predrag M. and Jokić, Bojan and Nikolić, Nebojša D.", year = "2016", abstract = "The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1 LT j(0)/j(L) LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1 LT j(0)/j(L) LT = 1. For j(0)/j(L) LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process.", publisher = "Serbian Chemical Society", journal = "Journal of the Serbian Chemical Society", title = "The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process", volume = "81", number = "3", pages = "291-306", doi = "10.2298/JSC150717076P" }
Popov, K. I., Živković, P. M., Jokić, B.,& Nikolić, N. D.. (2016). The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process. in Journal of the Serbian Chemical Society Serbian Chemical Society., 81(3), 291-306. https://doi.org/10.2298/JSC150717076P
Popov KI, Živković PM, Jokić B, Nikolić ND. The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process. in Journal of the Serbian Chemical Society. 2016;81(3):291-306. doi:10.2298/JSC150717076P .
Popov, Konstantin I., Živković, Predrag M., Jokić, Bojan, Nikolić, Nebojša D., "The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process" in Journal of the Serbian Chemical Society, 81, no. 3 (2016):291-306, https://doi.org/10.2298/JSC150717076P . .