ЦЕР - Централни Репозиторијум ИХТМ-а
Институт за хемију, технологију и металургију
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   ЦЕР
  • IHTM
  • Radovi istraživača / Researchers' publications
  • Преглед записа
  •   ЦЕР
  • IHTM
  • Radovi istraživača / Researchers' publications
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process

Thumbnail
2016
2004.pdf (598.1Kb)
Аутори
Popov, Konstantin I.
Živković, Predrag M.
Jokić, Bojan
Nikolić, Nebojša D.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1 LT j(0)/j(L) LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1 LT j(0)/j(L) LT = 1. For j(0)/j(L) LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process.
Кључне речи:
lead / zinc / copper / simulation / morphology / scanning electron microscopy
Извор:
Journal of the Serbian Chemical Society, 2016, 81, 3, 291-306
Издавач:
  • Serbian Chemical Society
Финансирање / пројекти:
  • Електрохемијска синтеза и карактеризација наноструктурираних функционалних материјала за примену у новим технологијама (RS-172046)

DOI: 10.2298/JSC150717076P

ISSN: 0352-5139

WoS: 000375398500007

Scopus: 2-s2.0-84971520492
[ Google Scholar ]
11
10
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/2006
Колекције
  • Radovi istraživača / Researchers' publications
Институција/група
IHTM
TY  - JOUR
AU  - Popov, Konstantin I.
AU  - Živković, Predrag M.
AU  - Jokić, Bojan
AU  - Nikolić, Nebojša D.
PY  - 2016
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/2006
AB  - The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1  LT  j(0)/j(L)  LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1  LT  j(0)/j(L)  LT = 1. For j(0)/j(L)  LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process.
PB  - Serbian Chemical Society
T2  - Journal of the Serbian Chemical Society
T1  - The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process
VL  - 81
IS  - 3
SP  - 291
EP  - 306
DO  - 10.2298/JSC150717076P
ER  - 
@article{
author = "Popov, Konstantin I. and Živković, Predrag M. and Jokić, Bojan and Nikolić, Nebojša D.",
year = "2016",
abstract = "The simulated shapes of the polarization curves were correlated with the type of metal electrodeposition process control as a function of the ratio of the exchange current density to the limiting diffusion current density (j(0)/j(L)). Diagnostic criteria based on the j(0)/j(L) ratios were established. For j(0)/j(L) > 100, the system is under the ohmic control. In the range 1  LT  j(0)/j(L)  LT = 100, there is mixed ohmic-diffusion control. Pure diffusion control appears in the range 0.1  LT  j(0)/j(L)  LT = 1. For j(0)/j(L)  LT = 0.1, the system is activation controlled at low overpotentials. The proposed diagnostic criteria were verified by comparison of the simulated curves with experimentally recorded ones and by morphological analysis of deposits obtained under the different types of control of the metal electrodeposition process.",
publisher = "Serbian Chemical Society",
journal = "Journal of the Serbian Chemical Society",
title = "The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process",
volume = "81",
number = "3",
pages = "291-306",
doi = "10.2298/JSC150717076P"
}
Popov, K. I., Živković, P. M., Jokić, B.,& Nikolić, N. D.. (2016). The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process. in Journal of the Serbian Chemical Society
Serbian Chemical Society., 81(3), 291-306.
https://doi.org/10.2298/JSC150717076P
Popov KI, Živković PM, Jokić B, Nikolić ND. The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process. in Journal of the Serbian Chemical Society. 2016;81(3):291-306.
doi:10.2298/JSC150717076P .
Popov, Konstantin I., Živković, Predrag M., Jokić, Bojan, Nikolić, Nebojša D., "The shape of the polarization curve and diagnostic criteria for control of the metal electrodeposition process" in Journal of the Serbian Chemical Society, 81, no. 3 (2016):291-306,
https://doi.org/10.2298/JSC150717076P . .

DSpace software copyright © 2002-2015  DuraSpace
О Централном репозиторијуму (ЦеР) | Пошаљите запажања

re3dataOpenAIRERCUB
 

 

Комплетан репозиторијумИнституције/групеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О Централном репозиторијуму (ЦеР) | Пошаљите запажања

re3dataOpenAIRERCUB