CER - Central Repository
Institute of Chemistry, Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
  •   CER
  • IHTM
  • Radovi istraživača / Researchers' publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Investigation of the microcantilevers by the photoacoustic elastic bending method

Authorized Users Only
2014
Authors
Todorović, D. M.
Jović, Vesna
Radulović, Katarina
Sarajlić, Milija
Markushev, D.
Rabasovic, M.D.
Conference object (Published version)
Metadata
Show full item record
Abstract
The amplitude of the photoacoustic (PA) elastic bending signals vs. the modulation frequency of the excitation optical beam for the chip with Si cantilevers were measured and analyzed. The experimental PA elastic bending signals of the whole micromechanical structure were measured by using special constructed PA cell (the gas-microphone detection technique with transmission configuration). The PA spectra were measured in a frequency range from 20 to 20000 Hz. The signal in the PA cell without optical excitation (noise) was also measured and analyzed. Experimental results show that the PA measuring system (PA cell width electret's microphone and lock-in amplifier) has signal-noise ratio S/N ∼ 30000 at 100 Hz; ∼ 3000 at 1000 Hz; ∼ 5 at 10000 Hz. The correction of the measured signal, in order to remove the coherent electronic noise as a systematic error, was made. The experimental PA elastic bending signals of the cantilever were compared with the experimental PA elastic bending signals ...of the Si square membranes. These results showed that the PA elastic bending method is convenient for investigation the characteristics of micromechanical structures as microcantilevers.

Source:
Proceedings of the International Conference on Microelectronics, ICM, 2014, 171-174
Publisher:
  • Institute of Electrical and Electronics Engineers Inc.

DOI: 10.1109/MIEL.2014.6842113

Scopus: 2-s2.0-84904701230
[ Google Scholar ]
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/1605
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - CONF
AU  - Todorović, D. M.
AU  - Jović, Vesna
AU  - Radulović, Katarina
AU  - Sarajlić, Milija
AU  - Markushev, D.
AU  - Rabasovic, M.D.
PY  - 2014
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/1605
AB  - The amplitude of the photoacoustic (PA) elastic bending signals vs. the modulation frequency of the excitation optical beam for the chip with Si cantilevers were measured and analyzed. The experimental PA elastic bending signals of the whole micromechanical structure were measured by using special constructed PA cell (the gas-microphone detection technique with transmission configuration). The PA spectra were measured in a frequency range from 20 to 20000 Hz. The signal in the PA cell without optical excitation (noise) was also measured and analyzed. Experimental results show that the PA measuring system (PA cell width electret's microphone and lock-in amplifier) has signal-noise ratio S/N ∼ 30000 at 100 Hz; ∼ 3000 at 1000 Hz; ∼ 5 at 10000 Hz. The correction of the measured signal, in order to remove the coherent electronic noise as a systematic error, was made. The experimental PA elastic bending signals of the cantilever were compared with the experimental PA elastic bending signals of the Si square membranes. These results showed that the PA elastic bending method is convenient for investigation the characteristics of micromechanical structures as microcantilevers.
PB  - Institute of Electrical and Electronics Engineers Inc.
C3  - Proceedings of the International Conference on Microelectronics, ICM
T1  - Investigation of the microcantilevers by the photoacoustic elastic bending method
SP  - 171
EP  - 174
DO  - 10.1109/MIEL.2014.6842113
ER  - 
@conference{
author = "Todorović, D. M. and Jović, Vesna and Radulović, Katarina and Sarajlić, Milija and Markushev, D. and Rabasovic, M.D.",
year = "2014",
abstract = "The amplitude of the photoacoustic (PA) elastic bending signals vs. the modulation frequency of the excitation optical beam for the chip with Si cantilevers were measured and analyzed. The experimental PA elastic bending signals of the whole micromechanical structure were measured by using special constructed PA cell (the gas-microphone detection technique with transmission configuration). The PA spectra were measured in a frequency range from 20 to 20000 Hz. The signal in the PA cell without optical excitation (noise) was also measured and analyzed. Experimental results show that the PA measuring system (PA cell width electret's microphone and lock-in amplifier) has signal-noise ratio S/N ∼ 30000 at 100 Hz; ∼ 3000 at 1000 Hz; ∼ 5 at 10000 Hz. The correction of the measured signal, in order to remove the coherent electronic noise as a systematic error, was made. The experimental PA elastic bending signals of the cantilever were compared with the experimental PA elastic bending signals of the Si square membranes. These results showed that the PA elastic bending method is convenient for investigation the characteristics of micromechanical structures as microcantilevers.",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
journal = "Proceedings of the International Conference on Microelectronics, ICM",
title = "Investigation of the microcantilevers by the photoacoustic elastic bending method",
pages = "171-174",
doi = "10.1109/MIEL.2014.6842113"
}
Todorović, D. M., Jović, V., Radulović, K., Sarajlić, M., Markushev, D.,& Rabasovic, M.D.. (2014). Investigation of the microcantilevers by the photoacoustic elastic bending method. in Proceedings of the International Conference on Microelectronics, ICM
Institute of Electrical and Electronics Engineers Inc.., 171-174.
https://doi.org/10.1109/MIEL.2014.6842113
Todorović DM, Jović V, Radulović K, Sarajlić M, Markushev D, Rabasovic M. Investigation of the microcantilevers by the photoacoustic elastic bending method. in Proceedings of the International Conference on Microelectronics, ICM. 2014;:171-174.
doi:10.1109/MIEL.2014.6842113 .
Todorović, D. M., Jović, Vesna, Radulović, Katarina, Sarajlić, Milija, Markushev, D., Rabasovic, M.D., "Investigation of the microcantilevers by the photoacoustic elastic bending method" in Proceedings of the International Conference on Microelectronics, ICM (2014):171-174,
https://doi.org/10.1109/MIEL.2014.6842113 . .

DSpace software copyright © 2002-2015  DuraSpace