The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement

Authorized Users Only
2014
Authors
Antonijevic, Djordje
Medigovic, Ivana
Zrilić, Milorad
Jokić, Bojan
Vuković, Zorica
Todorovic, Ljubomir
Article (Published version)
Metadata
Show full item record
Abstract
The aims of this study were to evaluate the radiopacity, compressive strength, setting time, and porosity of white Portland cement (PC) with the addition of bismuth oxide (Bi2O3), zirconium dioxide (ZrO2), and ytterbium trifluoride (YbF3) after immersion at 37 A degrees C for 7 days in distilled water or phosphate buffer saline. Specimens measuring 8 mm in diameter and 1 mm in thickness were fabricated from PC with the addition of 10, 20, and 30 wt% Bi2O3, ZrO2 or YbF3. ProRoot MTA (Dentsply, Tulsa, OK, USA) and pure PC were used as controls. For radiopacity assessments, specimens were radiographed alongside a tooth slices and an aluminum stepwedge on Extraspeed occlusal dental films (Insight Kodak, Rochester, New York). Mean optical density of each specimen was calculated and used to express radiopacity of the material as an equivalent thickness of aluminum. Compressive strength was measured by using 4-mm diameter and 6-mm high specimens and Universal testing machine. High-pressure me...rcury intrusion porosimeter (Carlo Erba Porosimeter 2000) was employed to measure the porosity of the specimens. The setting time was measured by using a needle of 100 g in weight. The morphology of specimens was evaluated using a scanning electron microscope (TESCAN Mira3 XMU, USA Inc.). Data were analyzed by one-way ANOVA and post hoc Tukey test (P LT 0.05). The PC with the addition of at least 10 wt% Bi2O3 and 20 wt% ZrO2 or YbF3 demonstrated greater radiopacity value than the recommended 3 mmAl cut-off. ZrO2 and YbF3 increased the compressive strength of PC, but it was not statistically significant (P > 0.05), while Bi2O3 decreased it (P LT 0.05). All radiopacifiers significantly increased the porosity of the experimental cements (P LT 0.05). Bi2O3 extended the setting time of PC (P LT 0.05), whilst ZrO2 and YbF3 did not significantly affect it (P > 0.05). ZrO2 and YbF3 may be used as a suitable alternative to replace Bi2O3 in MTA without influencing its physical properties.

Keywords:
Radiopacifying agents / Radiopacity / Compressive strength / Setting time / Porosity / Portland cement
Source:
Clinical Oral Investigations, 2014, 18, 6, 1597-1604
Publisher:
  • Springer Heidelberg, Heidelberg
Funding / projects:
  • Nanostructured Functional and Composite Materials in Catalytic and Sorption Processes (RS-45001)
  • Functional, Functionalized and Advanced Nanomaterials (RS-45005)

DOI: 10.1007/s00784-013-1130-0

ISSN: 1432-6981

PubMed: 24233183

WoS: 000338200000007

Scopus: 2-s2.0-84902787128
[ Google Scholar ]
27
21
URI
https://cer.ihtm.bg.ac.rs/handle/123456789/1555
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
IHTM
TY  - JOUR
AU  - Antonijevic, Djordje
AU  - Medigovic, Ivana
AU  - Zrilić, Milorad
AU  - Jokić, Bojan
AU  - Vuković, Zorica
AU  - Todorovic, Ljubomir
PY  - 2014
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/1555
AB  - The aims of this study were to evaluate the radiopacity, compressive strength, setting time, and porosity of white Portland cement (PC) with the addition of bismuth oxide (Bi2O3), zirconium dioxide (ZrO2), and ytterbium trifluoride (YbF3) after immersion at 37 A degrees C for 7 days in distilled water or phosphate buffer saline. Specimens measuring 8 mm in diameter and 1 mm in thickness were fabricated from PC with the addition of 10, 20, and 30 wt% Bi2O3, ZrO2 or YbF3. ProRoot MTA (Dentsply, Tulsa, OK, USA) and pure PC were used as controls. For radiopacity assessments, specimens were radiographed alongside a tooth slices and an aluminum stepwedge on Extraspeed occlusal dental films (Insight Kodak, Rochester, New York). Mean optical density of each specimen was calculated and used to express radiopacity of the material as an equivalent thickness of aluminum. Compressive strength was measured by using 4-mm diameter and 6-mm high specimens and Universal testing machine. High-pressure mercury intrusion porosimeter (Carlo Erba Porosimeter 2000) was employed to measure the porosity of the specimens. The setting time was measured by using a needle of 100 g in weight. The morphology of specimens was evaluated using a scanning electron microscope (TESCAN Mira3 XMU, USA Inc.). Data were analyzed by one-way ANOVA and post hoc Tukey test (P  LT  0.05). The PC with the addition of at least 10 wt% Bi2O3 and 20 wt% ZrO2 or YbF3 demonstrated greater radiopacity value than the recommended 3 mmAl cut-off. ZrO2 and YbF3 increased the compressive strength of PC, but it was not statistically significant (P > 0.05), while Bi2O3 decreased it (P  LT  0.05). All radiopacifiers significantly increased the porosity of the experimental cements (P  LT  0.05). Bi2O3 extended the setting time of PC (P  LT  0.05), whilst ZrO2 and YbF3 did not significantly affect it (P > 0.05). ZrO2 and YbF3 may be used as a suitable alternative to replace Bi2O3 in MTA without influencing its physical properties.
PB  - Springer Heidelberg, Heidelberg
T2  - Clinical Oral Investigations
T1  - The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement
VL  - 18
IS  - 6
SP  - 1597
EP  - 1604
DO  - 10.1007/s00784-013-1130-0
ER  - 
@article{
author = "Antonijevic, Djordje and Medigovic, Ivana and Zrilić, Milorad and Jokić, Bojan and Vuković, Zorica and Todorovic, Ljubomir",
year = "2014",
abstract = "The aims of this study were to evaluate the radiopacity, compressive strength, setting time, and porosity of white Portland cement (PC) with the addition of bismuth oxide (Bi2O3), zirconium dioxide (ZrO2), and ytterbium trifluoride (YbF3) after immersion at 37 A degrees C for 7 days in distilled water or phosphate buffer saline. Specimens measuring 8 mm in diameter and 1 mm in thickness were fabricated from PC with the addition of 10, 20, and 30 wt% Bi2O3, ZrO2 or YbF3. ProRoot MTA (Dentsply, Tulsa, OK, USA) and pure PC were used as controls. For radiopacity assessments, specimens were radiographed alongside a tooth slices and an aluminum stepwedge on Extraspeed occlusal dental films (Insight Kodak, Rochester, New York). Mean optical density of each specimen was calculated and used to express radiopacity of the material as an equivalent thickness of aluminum. Compressive strength was measured by using 4-mm diameter and 6-mm high specimens and Universal testing machine. High-pressure mercury intrusion porosimeter (Carlo Erba Porosimeter 2000) was employed to measure the porosity of the specimens. The setting time was measured by using a needle of 100 g in weight. The morphology of specimens was evaluated using a scanning electron microscope (TESCAN Mira3 XMU, USA Inc.). Data were analyzed by one-way ANOVA and post hoc Tukey test (P  LT  0.05). The PC with the addition of at least 10 wt% Bi2O3 and 20 wt% ZrO2 or YbF3 demonstrated greater radiopacity value than the recommended 3 mmAl cut-off. ZrO2 and YbF3 increased the compressive strength of PC, but it was not statistically significant (P > 0.05), while Bi2O3 decreased it (P  LT  0.05). All radiopacifiers significantly increased the porosity of the experimental cements (P  LT  0.05). Bi2O3 extended the setting time of PC (P  LT  0.05), whilst ZrO2 and YbF3 did not significantly affect it (P > 0.05). ZrO2 and YbF3 may be used as a suitable alternative to replace Bi2O3 in MTA without influencing its physical properties.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Clinical Oral Investigations",
title = "The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement",
volume = "18",
number = "6",
pages = "1597-1604",
doi = "10.1007/s00784-013-1130-0"
}
Antonijevic, D., Medigovic, I., Zrilić, M., Jokić, B., Vuković, Z.,& Todorovic, L.. (2014). The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement. in Clinical Oral Investigations
Springer Heidelberg, Heidelberg., 18(6), 1597-1604.
https://doi.org/10.1007/s00784-013-1130-0
Antonijevic D, Medigovic I, Zrilić M, Jokić B, Vuković Z, Todorovic L. The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement. in Clinical Oral Investigations. 2014;18(6):1597-1604.
doi:10.1007/s00784-013-1130-0 .
Antonijevic, Djordje, Medigovic, Ivana, Zrilić, Milorad, Jokić, Bojan, Vuković, Zorica, Todorovic, Ljubomir, "The influence of different radiopacifying agents on the radiopacity, compressive strength, setting time, and porosity of Portland cement" in Clinical Oral Investigations, 18, no. 6 (2014):1597-1604,
https://doi.org/10.1007/s00784-013-1130-0 . .

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About CeR – Central Repository | Send Feedback

re3dataOpenAIRERCUB