An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia

2013
Authors
Relić, Dubravka
Đorđević, Dragana

Sakan, Sanja

Anđelković, Ivan

Pantelić, Ana

Stanković, R.
Radojičić, A.
Popović, Aleksandar R.

Conference object (Published version)
Metadata
Show full item recordAbstract
We use conventional, microwave and ultrasound assisted sequential extraction, of defined time and power, techniques for extractions of Cd, Cu, Cr, Ni, Pb and Zn in sediments and certified material. We did not change the conditions of extractions through steps, cause we what to see is there difference in extraction results for the certified material and sediments. We use lower powers and time from microwave and ultrasound extraction in order to avoid additional heating and boiling of the samples. Steps 1-3 of the BCR (Community Bureau of Reference), excluding the hydrogen peroxide digestion in step 3, were completed in 16 h in the conventional, in 120 s with 90 W power of microwave and in 30 min of 42 kHz of an ultrasonic frequency. Digestion of organic matter with hydrogen peroxide was performed the same for all techniques. The fourth step, the pseudo-total content, was performed the same on samples remaining after performing the extraction of the previous three phases either conventio...nally, microwave-assisted or with ultrasound. The precision and accuracy of the proposed procedures were evaluated using a certified reference material BCR701. Acceptable accuracy for most of the metals was observed for all three steps of BCR protocol applying a 16 h total shaking period. Metals were determined with an acceptable accuracy after the pseudo-total step; expect Cr. Results obtained after the application of different techniques on sediments were comparable with ANOVA test for the 95 % of confidence level.
Keywords:
BCR / Danube alluvial sediments / Heavy metalsSource:
E3S Web of Conferences, 2013, 1Publisher:
- EDP Sciences
Funding / projects:
- Studying climate change and its influence on environment: impacts, adaptation and mitigation (RS-43007)
- The study of physicochemical and biochemical processes in living environment that have impacts on pollution and the investigation of possibilities for minimizing the consequences (RS-172001)
Collections
Institution/Community
IHTMTY - CONF AU - Relić, Dubravka AU - Đorđević, Dragana AU - Sakan, Sanja AU - Anđelković, Ivan AU - Pantelić, Ana AU - Stanković, R. AU - Radojičić, A. AU - Popović, Aleksandar R. PY - 2013 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/1370 AB - We use conventional, microwave and ultrasound assisted sequential extraction, of defined time and power, techniques for extractions of Cd, Cu, Cr, Ni, Pb and Zn in sediments and certified material. We did not change the conditions of extractions through steps, cause we what to see is there difference in extraction results for the certified material and sediments. We use lower powers and time from microwave and ultrasound extraction in order to avoid additional heating and boiling of the samples. Steps 1-3 of the BCR (Community Bureau of Reference), excluding the hydrogen peroxide digestion in step 3, were completed in 16 h in the conventional, in 120 s with 90 W power of microwave and in 30 min of 42 kHz of an ultrasonic frequency. Digestion of organic matter with hydrogen peroxide was performed the same for all techniques. The fourth step, the pseudo-total content, was performed the same on samples remaining after performing the extraction of the previous three phases either conventionally, microwave-assisted or with ultrasound. The precision and accuracy of the proposed procedures were evaluated using a certified reference material BCR701. Acceptable accuracy for most of the metals was observed for all three steps of BCR protocol applying a 16 h total shaking period. Metals were determined with an acceptable accuracy after the pseudo-total step; expect Cr. Results obtained after the application of different techniques on sediments were comparable with ANOVA test for the 95 % of confidence level. PB - EDP Sciences C3 - E3S Web of Conferences T1 - An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia VL - 1 DO - 10.1051/e3sconf/20130139002 ER -
@conference{ author = "Relić, Dubravka and Đorđević, Dragana and Sakan, Sanja and Anđelković, Ivan and Pantelić, Ana and Stanković, R. and Radojičić, A. and Popović, Aleksandar R.", year = "2013", abstract = "We use conventional, microwave and ultrasound assisted sequential extraction, of defined time and power, techniques for extractions of Cd, Cu, Cr, Ni, Pb and Zn in sediments and certified material. We did not change the conditions of extractions through steps, cause we what to see is there difference in extraction results for the certified material and sediments. We use lower powers and time from microwave and ultrasound extraction in order to avoid additional heating and boiling of the samples. Steps 1-3 of the BCR (Community Bureau of Reference), excluding the hydrogen peroxide digestion in step 3, were completed in 16 h in the conventional, in 120 s with 90 W power of microwave and in 30 min of 42 kHz of an ultrasonic frequency. Digestion of organic matter with hydrogen peroxide was performed the same for all techniques. The fourth step, the pseudo-total content, was performed the same on samples remaining after performing the extraction of the previous three phases either conventionally, microwave-assisted or with ultrasound. The precision and accuracy of the proposed procedures were evaluated using a certified reference material BCR701. Acceptable accuracy for most of the metals was observed for all three steps of BCR protocol applying a 16 h total shaking period. Metals were determined with an acceptable accuracy after the pseudo-total step; expect Cr. Results obtained after the application of different techniques on sediments were comparable with ANOVA test for the 95 % of confidence level.", publisher = "EDP Sciences", journal = "E3S Web of Conferences", title = "An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia", volume = "1", doi = "10.1051/e3sconf/20130139002" }
Relić, D., Đorđević, D., Sakan, S., Anđelković, I., Pantelić, A., Stanković, R., Radojičić, A.,& Popović, A. R.. (2013). An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia. in E3S Web of Conferences EDP Sciences., 1. https://doi.org/10.1051/e3sconf/20130139002
Relić D, Đorđević D, Sakan S, Anđelković I, Pantelić A, Stanković R, Radojičić A, Popović AR. An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia. in E3S Web of Conferences. 2013;1. doi:10.1051/e3sconf/20130139002 .
Relić, Dubravka, Đorđević, Dragana, Sakan, Sanja, Anđelković, Ivan, Pantelić, Ana, Stanković, R., Radojičić, A., Popović, Aleksandar R., "An appraisal of conventional, microwave and ultrasound BCR extraction methods for the analysis of metals in sediments of Pančevo, Serbia" in E3S Web of Conferences, 1 (2013), https://doi.org/10.1051/e3sconf/20130139002 . .