Приказ основних података о документу

dc.creatorGuzsvány, Valéria
dc.creatorPetrovic, Jelena
dc.creatorKrstić, Jugoslav
dc.creatorPapp, Zsigmond
dc.creatorPutek, Maria
dc.creatorBjelica, Luka
dc.creatorBobrowski, Andrzej
dc.creatorAbramović, Biljana F.
dc.date.accessioned2019-01-30T17:37:30Z
dc.date.available2019-01-30T17:37:30Z
dc.date.issued2013
dc.identifier.issn1572-6657
dc.identifier.urihttps://cer.ihtm.bg.ac.rs/handle/123456789/1334
dc.description.abstractA rapid and sensitive voltammetric method has been developed for the characterization and determination of the imidacloprid insecticide by means of square-wave voltammetry (SWV) with a silver-amalgam film electrode (Hg(Ag)FE) in the aqueous Britton-Robinson buffer solution as the supporting electrolyte. In the investigated pH range between 2.0 and 9.0 two reduction peaks of imidacloprid were observed, and they were both obtained in a fairly negative potential range, (approximately from -0.8 to -1.5 V). Their shape strongly depended on the pH of the supporting electrolyte. The analytical measurements, based on the first peak, were performed at the pH of 7.0, and imidacloprid was determined in the concentration range of 0.91-47.48 mu g cm(-3). The reproducibility of the analytical signal was characterized by a relative standard deviation smaller than 1.0%, and the calculated values of detection and quantitation limits were 0.27 mu g cm(-3) and 0.91 mu g cm(-3), respectively. The applicability of the elaborated SWV method was tested by monitoring imidacloprid concentration during its solar photolytic and photocatalytic degradation in the presence of two heterogeneous catalysts: TiO2 and TiO2 modified with 1.9% w/w Fe (1.9% Fe/TiO2). Under photolytic conditions, imidacloprid degraded very slowly, and the presence of TiO2 as a catalyst accelerated the process, while 1.9% Fe/TiO2 showed a remarkable efficiency in the removal of imidacloprid under natural insolation. In all investigated cases the results obtained using the Hg(Ag)FE-SWV method were in agreement with those obtained by means of the comparative HPLC-DAD method, which confirmed that the developed voltammetric method can be used to monitor the degradation of imidacloprid.en
dc.publisherElsevier
dc.relationEuropean Union - HU-SRB/0901/121/116 OCE-EFPTRWR
dc.relationSecretariat for Science and Technological Development of AP Vojvodina, Republic of Serbia - 114-451-02011/2007-02
dc.relationCEEPUS II network - CII-CZ-0212-04-1011
dc.relationCEEPUS III network - CIII-CZ-0212-05-1112
dc.rightsrestrictedAccess
dc.sourceJournal of Electroanalytical Chemistry
dc.subjectSilver-amalgam film electrodeen
dc.subjectImidaclopriden
dc.subjectVoltammetric monitoringen
dc.subjectSolar photodegradationen
dc.subjectFe/TiO2 catalysten
dc.titleRenewable silver-amalgam film electrode for voltammetric monitoring of solar photodegradation of imidacloprid in the presence of Fe/TiO2 and TiO2 catalystsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractПапп, Зсигмонд; Aбрамовић, Биљана Ф.; Крстић, Југослав; Петровиц, Јелена; Путек, Мариа; Бјелица, Лука; Боброwски, Aндрзеј; Гузсванy, Валериа;
dc.citation.volume699
dc.citation.spage33
dc.citation.epage39
dc.citation.other699: 33-39
dc.citation.rankM21
dc.identifier.doi10.1016/j.jelechem.2013.04.003
dc.identifier.scopus2-s2.0-84877318638
dc.identifier.wos000320211400007
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу