Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology

Нема приказа
Аутори
Nikolić, Maria Vesna
Aleksić, Obrad S.
Vasiljević-Radović, Dana
Nikolic, N.
Конференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
Multipolar anisotropy was induced in strontium hexaferrite green samples in a high intensity magnetic field during feedstock injection by PIM (powder injection molding) technology. Strontium hexaferrite particles in the melted feedstock were multipolarly aligned into four semi-circular paths that were circularly closed through a multipolar electromagnet. After debinding (with acetone and thermally) and sintering (optimized to obtain maximal values of the (BH)max product), samples were multipolarly magnetized again to form four poles on the outer surface of the sample. Multipolar anisotropy of the samples was observed and analyzed in detail by SEM and AFM (crystalline alignment) and by MFM (magnetical alignment).
Кључне речи:
Magnetic alignment / Multipolar anisotropy / PIM technology / Sr-hexaferrite
Извор:
Proceedings of the International Euro Powder Metallurgy Congress and Exhibition, Euro PM 2012, 2012, 3
Scopus: 2-s2.0-84902353913
[ Google Scholar ]
URI
http://cer.ihtm.bg.ac.rs/handle/123456789/1150
https://www.epma.com/publications/euro-pm-proceedings/product/ep12442
Колекције
  • Radovi istraživača / Researchers' publications
Институција
IHTM
TY  - CONF
AU  - Nikolić, Maria Vesna
AU  - Aleksić, Obrad S.
AU  - Vasiljević-Radović, Dana
AU  - Nikolic, N.
PY  - 2012
UR  - http://cer.ihtm.bg.ac.rs/handle/123456789/1150
UR  - https://www.epma.com/publications/euro-pm-proceedings/product/ep12442
AB  - Multipolar anisotropy was induced in strontium hexaferrite green samples in a high intensity magnetic field during feedstock injection by PIM (powder injection molding) technology. Strontium hexaferrite particles in the melted feedstock were multipolarly aligned into four semi-circular paths that were circularly closed through a multipolar electromagnet. After debinding (with acetone and thermally) and sintering (optimized to obtain maximal values of the (BH)max product), samples were multipolarly magnetized again to form four poles on the outer surface of the sample. Multipolar anisotropy of the samples was observed and analyzed in detail by SEM and AFM (crystalline alignment) and by MFM (magnetical alignment).
C3  - Proceedings of the International  Euro Powder Metallurgy Congress and Exhibition, Euro PM 2012
T1  - Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology
VL  - 3
ER  - 
@conference{
author = "Nikolić, Maria Vesna and Aleksić, Obrad S. and Vasiljević-Radović, Dana and Nikolic, N.",
year = "2012",
url = "http://cer.ihtm.bg.ac.rs/handle/123456789/1150, https://www.epma.com/publications/euro-pm-proceedings/product/ep12442",
abstract = "Multipolar anisotropy was induced in strontium hexaferrite green samples in a high intensity magnetic field during feedstock injection by PIM (powder injection molding) technology. Strontium hexaferrite particles in the melted feedstock were multipolarly aligned into four semi-circular paths that were circularly closed through a multipolar electromagnet. After debinding (with acetone and thermally) and sintering (optimized to obtain maximal values of the (BH)max product), samples were multipolarly magnetized again to form four poles on the outer surface of the sample. Multipolar anisotropy of the samples was observed and analyzed in detail by SEM and AFM (crystalline alignment) and by MFM (magnetical alignment).",
journal = "Proceedings of the International  Euro Powder Metallurgy Congress and Exhibition, Euro PM 2012",
title = "Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology",
volume = "3"
}
Nikolić MV, Aleksić OS, Vasiljević-Radović D, Nikolic N. Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology. Proceedings of the International  Euro Powder Metallurgy Congress and Exhibition, Euro PM 2012. 2012;3
Nikolić, M. V., Aleksić, O. S., Vasiljević-Radović, D.,& Nikolic, N. (2012). Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology.
Proceedings of the International  Euro Powder Metallurgy Congress and Exhibition, Euro PM 2012, 3.
Nikolić Maria Vesna, Aleksić Obrad S., Vasiljević-Radović Dana, Nikolic N., "Multipolar anisotropy and domain semicircular alignment in sintered strontium hexaferrite shaped by PIM technology" 3 (2012)

DSpace software copyright © 2002-2015  DuraSpace
О Централном репозиторијуму (ЦеР) | Пошаљите запажања

OpenAIRERCUB
 

 

Комплетан репозиторијумИнституцијеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О Централном репозиторијуму (ЦеР) | Пошаљите запажања

OpenAIRERCUB