Analysis of floating-head heat exchanger bolts failure
(Timisoara, Romania : SUDURA publising house, 2011)
As-received floating-head heat exchanger bolts were broken (BB) and deposite-coated. The aim was to estimatea cause of their failure. The new bolts of the same material were used as a reference material (reference bolt ...
Investigation of intergranular corrosion welded joint of austenitic stainless steel by electrochemical methods
(Timisoara, Romania : SUDURA publising house, 2011)
Sensitization degree of the austenitic stainless steel welded joints was investigated byelectrochemical methods: the double loop electrochemical potentiokinetic reactivation (DL EPR) in H2SO4 +KSCN solution and by of the ...