Office of Naval Research Global, Research Grant N62902-22-1-2024

Link to this page

Office of Naval Research Global, Research Grant N62902-22-1-2024

Authors

Publications

The comparison of two methods used to observe a nonlinear system: potentiometry and holography

Simović-Pavlović, Marina; Maksimović, Tijana; Maksimović, Jelena; Pagnacco, Maja

(Kragujevac, Serbia : Institute for Information Technologies, University of Kragujevac, 2023)

TY  - CONF
AU  - Simović-Pavlović, Marina
AU  - Maksimović, Tijana
AU  - Maksimović, Jelena
AU  - Pagnacco, Maja
PY  - 2023
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/7364
AB  - The transition from state I ( characterized by low iodide and iodine concentration) to state II (high iodide and iodine concentration) occurs in a nonlinear Briggs-Rauscher (BR) oscillatory reaction. This transition was studied by two methods: potentiometric and holographic. The first derivative technique was applied to the obtained electrochemical and holographic curves of the transition state I→state II to obtain the corresponding slopes. Based on these slopes, the results of the two methods are compared. The obtained holographic slope for the transition from state I to state II is higher than the potentiometric one in all selected reaction sections. In the initial phase of the transition from state I to state II, it is clear that the velocity of the holographic method is twice that of the potentiometric method. While this trend shows a twofold increase at the beginning of the phase transition, it deviates in the other phases, where the holographic measurements show a 1.5-fold higher rate in the middle. The obtained results could have a strong impact on the study of nonlinear systems in the future.
PB  - Kragujevac, Serbia : Institute for Information Technologies, University of Kragujevac
C3  - 2nd International Conference on Chemo and  Bioinformatics - Book of proceedings,  September 28-29, 2023. Kragujevac, Serbia
T1  - The comparison of two methods used to observe a nonlinear system: potentiometry and holography
SP  - 164
EP  - 167
DO  - 10.46793/ICCBI23.164SP
ER  - 
@conference{
author = "Simović-Pavlović, Marina and Maksimović, Tijana and Maksimović, Jelena and Pagnacco, Maja",
year = "2023",
abstract = "The transition from state I ( characterized by low iodide and iodine concentration) to state II (high iodide and iodine concentration) occurs in a nonlinear Briggs-Rauscher (BR) oscillatory reaction. This transition was studied by two methods: potentiometric and holographic. The first derivative technique was applied to the obtained electrochemical and holographic curves of the transition state I→state II to obtain the corresponding slopes. Based on these slopes, the results of the two methods are compared. The obtained holographic slope for the transition from state I to state II is higher than the potentiometric one in all selected reaction sections. In the initial phase of the transition from state I to state II, it is clear that the velocity of the holographic method is twice that of the potentiometric method. While this trend shows a twofold increase at the beginning of the phase transition, it deviates in the other phases, where the holographic measurements show a 1.5-fold higher rate in the middle. The obtained results could have a strong impact on the study of nonlinear systems in the future.",
publisher = "Kragujevac, Serbia : Institute for Information Technologies, University of Kragujevac",
journal = "2nd International Conference on Chemo and  Bioinformatics - Book of proceedings,  September 28-29, 2023. Kragujevac, Serbia",
title = "The comparison of two methods used to observe a nonlinear system: potentiometry and holography",
pages = "164-167",
doi = "10.46793/ICCBI23.164SP"
}
Simović-Pavlović, M., Maksimović, T., Maksimović, J.,& Pagnacco, M.. (2023). The comparison of two methods used to observe a nonlinear system: potentiometry and holography. in 2nd International Conference on Chemo and  Bioinformatics - Book of proceedings,  September 28-29, 2023. Kragujevac, Serbia
Kragujevac, Serbia : Institute for Information Technologies, University of Kragujevac., 164-167.
https://doi.org/10.46793/ICCBI23.164SP
Simović-Pavlović M, Maksimović T, Maksimović J, Pagnacco M. The comparison of two methods used to observe a nonlinear system: potentiometry and holography. in 2nd International Conference on Chemo and  Bioinformatics - Book of proceedings,  September 28-29, 2023. Kragujevac, Serbia. 2023;:164-167.
doi:10.46793/ICCBI23.164SP .
Simović-Pavlović, Marina, Maksimović, Tijana, Maksimović, Jelena, Pagnacco, Maja, "The comparison of two methods used to observe a nonlinear system: potentiometry and holography" in 2nd International Conference on Chemo and  Bioinformatics - Book of proceedings,  September 28-29, 2023. Kragujevac, Serbia (2023):164-167,
https://doi.org/10.46793/ICCBI23.164SP . .