Kalcher, Kurt

Link to this page

Authority KeyName Variants
cb2eafc8-c3d1-4065-99c2-20ea6a8bd7cc
  • Kalcher, Kurt (9)

Author's Bibliography

Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application

Đurđić, Slađana; Stanković, Vesna; Vlahović, Filip; Ognjanović, Miloš; Kalcher, Kurt; Ćirković Veličković, T.; Mutić, Jelena; Stanković, Dalibor M.

(The Electrochemical Society ("ECS")., 2021)

TY  - JOUR
AU  - Đurđić, Slađana
AU  - Stanković, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Kalcher, Kurt
AU  - Ćirković Veličković, T.
AU  - Mutić, Jelena
AU  - Stanković, Dalibor M.
PY  - 2021
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/4523
AB  - Based on graphene nanoplatelets capability to build block composites, as well as well-known electrochemical characteristic of the manganese oxide materials, in the present research, a nanocomposite, formed from graphene nanoplatelets (GNP) and manganese(IV)-oxide (MnO2) nanoparticles, has been proposed as a novel and convenient support for enzyme immobilization. Performance of screen printed carbon electrodes (SPCEs) was significantly improved after their modification with GNP@MnO2 (SPCE/GNP@MnO2). The polyphenolic index biosensor was prepared by applying the drop coating technique using laccase and Nafion®. Developed biosensor shows a fast and reliable amperometric response toward caffeic acid, as a model compound, at operating potential of +0.40 V (vs Ag/AgCl), with a wide linear range and detection limit of 1.9 μmol l-1. Developed procedure was successfully applied for the determination of polyphenolic indexes in wine samples. Recovery tests indicate excellent accuracy and precision of the method, concluding that the biosensor can offer a fast, accurate, reliable and precise determination of the polyphenolic index. More importantly, our results suggest a great potential for the application in real samples. © 2021 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
PB  - The Electrochemical Society ("ECS").
T2  - Journal of Electrochemical Society
T1  - Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application
VL  - 168
IS  - 3
SP  - 037510
DO  - 10.1149/1945-7111/abeaf2
ER  - 
@article{
author = "Đurđić, Slađana and Stanković, Vesna and Vlahović, Filip and Ognjanović, Miloš and Kalcher, Kurt and Ćirković Veličković, T. and Mutić, Jelena and Stanković, Dalibor M.",
year = "2021",
abstract = "Based on graphene nanoplatelets capability to build block composites, as well as well-known electrochemical characteristic of the manganese oxide materials, in the present research, a nanocomposite, formed from graphene nanoplatelets (GNP) and manganese(IV)-oxide (MnO2) nanoparticles, has been proposed as a novel and convenient support for enzyme immobilization. Performance of screen printed carbon electrodes (SPCEs) was significantly improved after their modification with GNP@MnO2 (SPCE/GNP@MnO2). The polyphenolic index biosensor was prepared by applying the drop coating technique using laccase and Nafion®. Developed biosensor shows a fast and reliable amperometric response toward caffeic acid, as a model compound, at operating potential of +0.40 V (vs Ag/AgCl), with a wide linear range and detection limit of 1.9 μmol l-1. Developed procedure was successfully applied for the determination of polyphenolic indexes in wine samples. Recovery tests indicate excellent accuracy and precision of the method, concluding that the biosensor can offer a fast, accurate, reliable and precise determination of the polyphenolic index. More importantly, our results suggest a great potential for the application in real samples. © 2021 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.",
publisher = "The Electrochemical Society ("ECS").",
journal = "Journal of Electrochemical Society",
title = "Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application",
volume = "168",
number = "3",
pages = "037510",
doi = "10.1149/1945-7111/abeaf2"
}
Đurđić, S., Stanković, V., Vlahović, F., Ognjanović, M., Kalcher, K., Ćirković Veličković, T., Mutić, J.,& Stanković, D. M.. (2021). Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application. in Journal of Electrochemical Society
The Electrochemical Society ("ECS").., 168(3), 037510.
https://doi.org/10.1149/1945-7111/abeaf2
Đurđić S, Stanković V, Vlahović F, Ognjanović M, Kalcher K, Ćirković Veličković T, Mutić J, Stanković DM. Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application. in Journal of Electrochemical Society. 2021;168(3):037510.
doi:10.1149/1945-7111/abeaf2 .
Đurđić, Slađana, Stanković, Vesna, Vlahović, Filip, Ognjanović, Miloš, Kalcher, Kurt, Ćirković Veličković, T., Mutić, Jelena, Stanković, Dalibor M., "Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application" in Journal of Electrochemical Society, 168, no. 3 (2021):037510,
https://doi.org/10.1149/1945-7111/abeaf2 . .
11
2
9

Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application

Đurđić, Slađana; Stanković, Vesna; Vlahović, Filip; Ognjanović, Miloš; Kalcher, Kurt; Ćirković Veličković, T.; Mutić, Jelena; Stanković, Dalibor M.

(The Electrochemical Society ("ECS")., 2021)

TY  - JOUR
AU  - Đurđić, Slađana
AU  - Stanković, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Kalcher, Kurt
AU  - Ćirković Veličković, T.
AU  - Mutić, Jelena
AU  - Stanković, Dalibor M.
PY  - 2021
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/4578
AB  - Based on graphene nanoplatelets capability to build block composites, as well as well-known electrochemical characteristic of the manganese oxide materials, in the present research, a nanocomposite, formed from graphene nanoplatelets (GNP) and manganese(IV)-oxide (MnO2) nanoparticles, has been proposed as a novel and convenient support for enzyme immobilization. Performance of screen printed carbon electrodes (SPCEs) was significantly improved after their modification with GNP@MnO2 (SPCE/GNP@MnO2). The polyphenolic index biosensor was prepared by applying the drop coating technique using laccase and Nafion®. Developed biosensor shows a fast and reliable amperometric response toward caffeic acid, as a model compound, at operating potential of +0.40 V (vs Ag/AgCl), with a wide linear range and detection limit of 1.9 μmol l-1. Developed procedure was successfully applied for the determination of polyphenolic indexes in wine samples. Recovery tests indicate excellent accuracy and precision of the method, concluding that the biosensor can offer a fast, accurate, reliable and precise determination of the polyphenolic index. More importantly, our results suggest a great potential for the application in real samples. © 2021 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
PB  - The Electrochemical Society ("ECS").
T2  - Journal of Electrochemical Society
T1  - Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application
VL  - 168
IS  - 3
SP  - 037510
DO  - 10.1149/1945-7111/abeaf2
ER  - 
@article{
author = "Đurđić, Slađana and Stanković, Vesna and Vlahović, Filip and Ognjanović, Miloš and Kalcher, Kurt and Ćirković Veličković, T. and Mutić, Jelena and Stanković, Dalibor M.",
year = "2021",
abstract = "Based on graphene nanoplatelets capability to build block composites, as well as well-known electrochemical characteristic of the manganese oxide materials, in the present research, a nanocomposite, formed from graphene nanoplatelets (GNP) and manganese(IV)-oxide (MnO2) nanoparticles, has been proposed as a novel and convenient support for enzyme immobilization. Performance of screen printed carbon electrodes (SPCEs) was significantly improved after their modification with GNP@MnO2 (SPCE/GNP@MnO2). The polyphenolic index biosensor was prepared by applying the drop coating technique using laccase and Nafion®. Developed biosensor shows a fast and reliable amperometric response toward caffeic acid, as a model compound, at operating potential of +0.40 V (vs Ag/AgCl), with a wide linear range and detection limit of 1.9 μmol l-1. Developed procedure was successfully applied for the determination of polyphenolic indexes in wine samples. Recovery tests indicate excellent accuracy and precision of the method, concluding that the biosensor can offer a fast, accurate, reliable and precise determination of the polyphenolic index. More importantly, our results suggest a great potential for the application in real samples. © 2021 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.",
publisher = "The Electrochemical Society ("ECS").",
journal = "Journal of Electrochemical Society",
title = "Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application",
volume = "168",
number = "3",
pages = "037510",
doi = "10.1149/1945-7111/abeaf2"
}
Đurđić, S., Stanković, V., Vlahović, F., Ognjanović, M., Kalcher, K., Ćirković Veličković, T., Mutić, J.,& Stanković, D. M.. (2021). Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application. in Journal of Electrochemical Society
The Electrochemical Society ("ECS").., 168(3), 037510.
https://doi.org/10.1149/1945-7111/abeaf2
Đurđić S, Stanković V, Vlahović F, Ognjanović M, Kalcher K, Ćirković Veličković T, Mutić J, Stanković DM. Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application. in Journal of Electrochemical Society. 2021;168(3):037510.
doi:10.1149/1945-7111/abeaf2 .
Đurđić, Slađana, Stanković, Vesna, Vlahović, Filip, Ognjanović, Miloš, Kalcher, Kurt, Ćirković Veličković, T., Mutić, Jelena, Stanković, Dalibor M., "Laccase Polyphenolic Biosensor Supported on MnO2@GNP Decorated SPCE: Preparation, Characterization, and Analytical Application" in Journal of Electrochemical Society, 168, no. 3 (2021):037510,
https://doi.org/10.1149/1945-7111/abeaf2 . .
11
2
9

Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection

Đurđić, Slađana; Stanković, Vesna; Vlahović, Filip; Ognjanović, Miloš; Kalcher, Kurt; Manojlović, Dragan; Mutić, Jelena; Stanković, Dalibor M.

(Elsevier, 2021)

TY  - JOUR
AU  - Đurđić, Slađana
AU  - Stanković, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Kalcher, Kurt
AU  - Manojlović, Dragan
AU  - Mutić, Jelena
AU  - Stanković, Dalibor M.
PY  - 2021
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/4683
AB  - L-DOPA (L-3,4-dihydroxyphenylalanine), the precursor of dopamine, is widely used in the treatment of Parkinson’s disease, thus determining and monitoring the concentration of L-DOPA is of utmost importance for both medical and scientific purposes. Although many analytical approaches, designed for drug detection and quantification, already exist, there is a constant need for modification of old and tailoring of new, faster, and selective methods. Redox active chemical species, such as L-DOPA, can be measured directly by electrochemical means, whereas electrochemical sensors combine sensitivity and selectivity within a small analytical device. This work demonstrates the development of such electrochemical sensor, based on carboxylated single-wall carbon nanotubes (SWCNT-COOH) decorated with SiO2 coated-Nd2O3 nanoparticles, and further application for the detection of L-DOPA. Developed SWCNT-COOH@Nd2O3-SiO2 sensor shows linear response in the range from 2 µmol L−1 to 52 µmol L−1 analyte concentration, and beside the low detection limit, it is characterized by a fast response time, as well as good life-time, reproducibility and repeatability.
PB  - Elsevier
T2  - Microchemical Journal
T1  - Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection
VL  - 168
SP  - 106416
DO  - 10.1016/j.microc.2021.106416
ER  - 
@article{
author = "Đurđić, Slađana and Stanković, Vesna and Vlahović, Filip and Ognjanović, Miloš and Kalcher, Kurt and Manojlović, Dragan and Mutić, Jelena and Stanković, Dalibor M.",
year = "2021",
abstract = "L-DOPA (L-3,4-dihydroxyphenylalanine), the precursor of dopamine, is widely used in the treatment of Parkinson’s disease, thus determining and monitoring the concentration of L-DOPA is of utmost importance for both medical and scientific purposes. Although many analytical approaches, designed for drug detection and quantification, already exist, there is a constant need for modification of old and tailoring of new, faster, and selective methods. Redox active chemical species, such as L-DOPA, can be measured directly by electrochemical means, whereas electrochemical sensors combine sensitivity and selectivity within a small analytical device. This work demonstrates the development of such electrochemical sensor, based on carboxylated single-wall carbon nanotubes (SWCNT-COOH) decorated with SiO2 coated-Nd2O3 nanoparticles, and further application for the detection of L-DOPA. Developed SWCNT-COOH@Nd2O3-SiO2 sensor shows linear response in the range from 2 µmol L−1 to 52 µmol L−1 analyte concentration, and beside the low detection limit, it is characterized by a fast response time, as well as good life-time, reproducibility and repeatability.",
publisher = "Elsevier",
journal = "Microchemical Journal",
title = "Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection",
volume = "168",
pages = "106416",
doi = "10.1016/j.microc.2021.106416"
}
Đurđić, S., Stanković, V., Vlahović, F., Ognjanović, M., Kalcher, K., Manojlović, D., Mutić, J.,& Stanković, D. M.. (2021). Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection. in Microchemical Journal
Elsevier., 168, 106416.
https://doi.org/10.1016/j.microc.2021.106416
Đurđić S, Stanković V, Vlahović F, Ognjanović M, Kalcher K, Manojlović D, Mutić J, Stanković DM. Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection. in Microchemical Journal. 2021;168:106416.
doi:10.1016/j.microc.2021.106416 .
Đurđić, Slađana, Stanković, Vesna, Vlahović, Filip, Ognjanović, Miloš, Kalcher, Kurt, Manojlović, Dragan, Mutić, Jelena, Stanković, Dalibor M., "Carboxylated single-wall carbon nanotubes decorated with SiO2 coated-Nd2O3 nanoparticles as an electrochemical sensor for L-DOPA detection" in Microchemical Journal, 168 (2021):106416,
https://doi.org/10.1016/j.microc.2021.106416 . .
33
31

Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor

Stanković, Vesna; Đurđić, Slađana; Ognjanović, Miloš; Antić, Bratislav; Kalcher, Kurt; Mutić, Jelena; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Stanković, Vesna
AU  - Đurđić, Slađana
AU  - Ognjanović, Miloš
AU  - Antić, Bratislav
AU  - Kalcher, Kurt
AU  - Mutić, Jelena
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3419
AB  - Diagnosis and treatment of some important diseased and metabolic disorders is based on successful detection of albumin. In this work, we aim to develop a simple immunosensor for the detection of human serum albumin in biological fluids. Anti-human albumin antibody was covalently attached to the activated surface of screen-printed carbon electrodes enriched with carboxyl graphene/gold nanoparticles composite. Microstructure (TEM, FE-SEM, XRD) and electrochemical (CV, EIS) characterization methods were used to investigate composite properties and to confirm the successful modification of the electrodes. Under the optimal conditions, linear working range and limit of detection were 2.5–500 μg/mL and 1.55 μg/mL, respectively. Additionally, the effect of some possibly interfering compounds was investigated and the immunosensor was used for real sample analysis. The results showed that the sensor exhibited accurate, precise and sensitive characteristics and can be promising replacement to the convention methods for albumin detection in clinical practice.
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor
VL  - 860
SP  - 113928
DO  - 10.1016/j.jelechem.2020.113928
ER  - 
@article{
author = "Stanković, Vesna and Đurđić, Slađana and Ognjanović, Miloš and Antić, Bratislav and Kalcher, Kurt and Mutić, Jelena and Stanković, Dalibor",
year = "2020",
abstract = "Diagnosis and treatment of some important diseased and metabolic disorders is based on successful detection of albumin. In this work, we aim to develop a simple immunosensor for the detection of human serum albumin in biological fluids. Anti-human albumin antibody was covalently attached to the activated surface of screen-printed carbon electrodes enriched with carboxyl graphene/gold nanoparticles composite. Microstructure (TEM, FE-SEM, XRD) and electrochemical (CV, EIS) characterization methods were used to investigate composite properties and to confirm the successful modification of the electrodes. Under the optimal conditions, linear working range and limit of detection were 2.5–500 μg/mL and 1.55 μg/mL, respectively. Additionally, the effect of some possibly interfering compounds was investigated and the immunosensor was used for real sample analysis. The results showed that the sensor exhibited accurate, precise and sensitive characteristics and can be promising replacement to the convention methods for albumin detection in clinical practice.",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor",
volume = "860",
pages = "113928",
doi = "10.1016/j.jelechem.2020.113928"
}
Stanković, V., Đurđić, S., Ognjanović, M., Antić, B., Kalcher, K., Mutić, J.,& Stanković, D.. (2020). Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor. in Journal of Electroanalytical Chemistry
Elsevier., 860, 113928.
https://doi.org/10.1016/j.jelechem.2020.113928
Stanković V, Đurđić S, Ognjanović M, Antić B, Kalcher K, Mutić J, Stanković D. Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor. in Journal of Electroanalytical Chemistry. 2020;860:113928.
doi:10.1016/j.jelechem.2020.113928 .
Stanković, Vesna, Đurđić, Slađana, Ognjanović, Miloš, Antić, Bratislav, Kalcher, Kurt, Mutić, Jelena, Stanković, Dalibor, "Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor" in Journal of Electroanalytical Chemistry, 860 (2020):113928,
https://doi.org/10.1016/j.jelechem.2020.113928 . .
43
15
38

Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor

Stanković, Vesna; Đurđić, Slađana; Ognjanović, Miloš; Antić, Bratislav; Kalcher, Kurt; Mutić, Jelena; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Stanković, Vesna
AU  - Đurđić, Slađana
AU  - Ognjanović, Miloš
AU  - Antić, Bratislav
AU  - Kalcher, Kurt
AU  - Mutić, Jelena
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3420
AB  - Diagnosis and treatment of some important diseased and metabolic disorders is based on successful detection of albumin. In this work, we aim to develop a simple immunosensor for the detection of human serum albumin in biological fluids. Anti-human albumin antibody was covalently attached to the activated surface of screen-printed carbon electrodes enriched with carboxyl graphene/gold nanoparticles composite. Microstructure (TEM, FE-SEM, XRD) and electrochemical (CV, EIS) characterization methods were used to investigate composite properties and to confirm the successful modification of the electrodes. Under the optimal conditions, linear working range and limit of detection were 2.5–500 μg/mL and 1.55 μg/mL, respectively. Additionally, the effect of some possibly interfering compounds was investigated and the immunosensor was used for real sample analysis. The results showed that the sensor exhibited accurate, precise and sensitive characteristics and can be promising replacement to the convention methods for albumin detection in clinical practice.
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor
VL  - 860
SP  - 113928
DO  - 10.1016/j.jelechem.2020.113928
ER  - 
@article{
author = "Stanković, Vesna and Đurđić, Slađana and Ognjanović, Miloš and Antić, Bratislav and Kalcher, Kurt and Mutić, Jelena and Stanković, Dalibor",
year = "2020",
abstract = "Diagnosis and treatment of some important diseased and metabolic disorders is based on successful detection of albumin. In this work, we aim to develop a simple immunosensor for the detection of human serum albumin in biological fluids. Anti-human albumin antibody was covalently attached to the activated surface of screen-printed carbon electrodes enriched with carboxyl graphene/gold nanoparticles composite. Microstructure (TEM, FE-SEM, XRD) and electrochemical (CV, EIS) characterization methods were used to investigate composite properties and to confirm the successful modification of the electrodes. Under the optimal conditions, linear working range and limit of detection were 2.5–500 μg/mL and 1.55 μg/mL, respectively. Additionally, the effect of some possibly interfering compounds was investigated and the immunosensor was used for real sample analysis. The results showed that the sensor exhibited accurate, precise and sensitive characteristics and can be promising replacement to the convention methods for albumin detection in clinical practice.",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor",
volume = "860",
pages = "113928",
doi = "10.1016/j.jelechem.2020.113928"
}
Stanković, V., Đurđić, S., Ognjanović, M., Antić, B., Kalcher, K., Mutić, J.,& Stanković, D.. (2020). Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor. in Journal of Electroanalytical Chemistry
Elsevier., 860, 113928.
https://doi.org/10.1016/j.jelechem.2020.113928
Stanković V, Đurđić S, Ognjanović M, Antić B, Kalcher K, Mutić J, Stanković D. Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor. in Journal of Electroanalytical Chemistry. 2020;860:113928.
doi:10.1016/j.jelechem.2020.113928 .
Stanković, Vesna, Đurđić, Slađana, Ognjanović, Miloš, Antić, Bratislav, Kalcher, Kurt, Mutić, Jelena, Stanković, Dalibor, "Anti-human albumin monoclonal antibody immobilized on EDC-NHS functionalized carboxylic graphene/AuNPs composite as promising electrochemical HSA immunosensor" in Journal of Electroanalytical Chemistry, 860 (2020):113928,
https://doi.org/10.1016/j.jelechem.2020.113928 . .
43
15
38

A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode

Stanković, Vesna; Đurđić, Slađana; Ognjanović, Miloš; Mutić, Jelena; Kalcher, Kurt; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Stanković, Vesna
AU  - Đurđić, Slađana
AU  - Ognjanović, Miloš
AU  - Mutić, Jelena
AU  - Kalcher, Kurt
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3612
AB  - A nonenzymatic hydrogen-peroxide sensor was developed by utilization of silver nanoparticles and graphene
nanoribbons. The mentioned composite was inflicted on a screen-printed carbon electrode which provides disposable,
ready-to-use sensor. The structure and morphology of the nanocomposite were analyzed by scanning electron microscopy
and X-ray diffraction. The sensor has excellent performance toward H2O2 amperometric detection. Figures of
merit include dynamic response range from 0.05 to 5 mM and detection limit of 20 μM (at S/N =3). The fabricated
sensor was used for the determination ofH2O2 in milk samples. The obtained results showed that the proposed AgNp@
GNR/SPCE sensor can be used for the determination of hydrogen peroxide in real samples.
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode
VL  - 876
SP  - 114487
DO  - 10.1016/j.jelechem.2020.114487
ER  - 
@article{
author = "Stanković, Vesna and Đurđić, Slađana and Ognjanović, Miloš and Mutić, Jelena and Kalcher, Kurt and Stanković, Dalibor",
year = "2020",
abstract = "A nonenzymatic hydrogen-peroxide sensor was developed by utilization of silver nanoparticles and graphene
nanoribbons. The mentioned composite was inflicted on a screen-printed carbon electrode which provides disposable,
ready-to-use sensor. The structure and morphology of the nanocomposite were analyzed by scanning electron microscopy
and X-ray diffraction. The sensor has excellent performance toward H2O2 amperometric detection. Figures of
merit include dynamic response range from 0.05 to 5 mM and detection limit of 20 μM (at S/N =3). The fabricated
sensor was used for the determination ofH2O2 in milk samples. The obtained results showed that the proposed AgNp@
GNR/SPCE sensor can be used for the determination of hydrogen peroxide in real samples.",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode",
volume = "876",
pages = "114487",
doi = "10.1016/j.jelechem.2020.114487"
}
Stanković, V., Đurđić, S., Ognjanović, M., Mutić, J., Kalcher, K.,& Stanković, D.. (2020). A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode. in Journal of Electroanalytical Chemistry
Elsevier., 876, 114487.
https://doi.org/10.1016/j.jelechem.2020.114487
Stanković V, Đurđić S, Ognjanović M, Mutić J, Kalcher K, Stanković D. A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode. in Journal of Electroanalytical Chemistry. 2020;876:114487.
doi:10.1016/j.jelechem.2020.114487 .
Stanković, Vesna, Đurđić, Slađana, Ognjanović, Miloš, Mutić, Jelena, Kalcher, Kurt, Stanković, Dalibor, "A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode" in Journal of Electroanalytical Chemistry, 876 (2020):114487,
https://doi.org/10.1016/j.jelechem.2020.114487 . .
35
14
35

A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode

Stanković, Vesna; Đurđić, Slađana; Ognjanović, Miloš; Mutić, Jelena; Kalcher, Kurt; Stanković, Dalibor

(Elsevier, 2020)

TY  - JOUR
AU  - Stanković, Vesna
AU  - Đurđić, Slađana
AU  - Ognjanović, Miloš
AU  - Mutić, Jelena
AU  - Kalcher, Kurt
AU  - Stanković, Dalibor
PY  - 2020
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3613
AB  - A nonenzymatic hydrogen-peroxide sensor was developed by utilization of silver nanoparticles and graphenenanoribbons. The mentioned composite was inflicted on a screen-printed carbon electrode which provides disposable,ready-to-use sensor. The structure and morphology of the nanocomposite were analyzed by scanning electron microscopyand X-ray diffraction. The sensor has excellent performance toward H2O2 amperometric detection. Figures ofmerit include dynamic response range from 0.05 to 5 mM and detection limit of 20 μM (at S/N =3). The fabricatedsensor was used for the determination ofH2O2 in milk samples. The obtained results showed that the proposed AgNp@GNR/SPCE sensor can be used for the determination of hydrogen peroxide in real samples.
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode
VL  - 876
SP  - 114487
DO  - 10.1016/j.jelechem.2020.114487
ER  - 
@article{
author = "Stanković, Vesna and Đurđić, Slađana and Ognjanović, Miloš and Mutić, Jelena and Kalcher, Kurt and Stanković, Dalibor",
year = "2020",
abstract = "A nonenzymatic hydrogen-peroxide sensor was developed by utilization of silver nanoparticles and graphenenanoribbons. The mentioned composite was inflicted on a screen-printed carbon electrode which provides disposable,ready-to-use sensor. The structure and morphology of the nanocomposite were analyzed by scanning electron microscopyand X-ray diffraction. The sensor has excellent performance toward H2O2 amperometric detection. Figures ofmerit include dynamic response range from 0.05 to 5 mM and detection limit of 20 μM (at S/N =3). The fabricatedsensor was used for the determination ofH2O2 in milk samples. The obtained results showed that the proposed AgNp@GNR/SPCE sensor can be used for the determination of hydrogen peroxide in real samples.",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode",
volume = "876",
pages = "114487",
doi = "10.1016/j.jelechem.2020.114487"
}
Stanković, V., Đurđić, S., Ognjanović, M., Mutić, J., Kalcher, K.,& Stanković, D.. (2020). A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode. in Journal of Electroanalytical Chemistry
Elsevier., 876, 114487.
https://doi.org/10.1016/j.jelechem.2020.114487
Stanković V, Đurđić S, Ognjanović M, Mutić J, Kalcher K, Stanković D. A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode. in Journal of Electroanalytical Chemistry. 2020;876:114487.
doi:10.1016/j.jelechem.2020.114487 .
Stanković, Vesna, Đurđić, Slađana, Ognjanović, Miloš, Mutić, Jelena, Kalcher, Kurt, Stanković, Dalibor, "A novel nonenzymatic hydrogen peroxide amperometric sensor based on AgNp@GNR nanocomposites modified screen-printed carbon electrode" in Journal of Electroanalytical Chemistry, 876 (2020):114487,
https://doi.org/10.1016/j.jelechem.2020.114487 . .
35
14
35

Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing

Đurđić, Slađana; Vukojević, Vesna; Vlahović, Filip; Ognjanović, Miloš; Švorc, jubomir; Kalcher, Kurt; Mutić, Jelena; Stanković, Dalibor

(Elsevier, 2019)

TY  - JOUR
AU  - Đurđić, Slađana
AU  - Vukojević, Vesna
AU  - Vlahović, Filip
AU  - Ognjanović, Miloš
AU  - Švorc, jubomir
AU  - Kalcher, Kurt
AU  - Mutić, Jelena
AU  - Stanković, Dalibor
PY  - 2019
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3224
PB  - Elsevier
T2  - Journal of Electroanalytical Chemistry
T1  - Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing
VL  - 850
DO  - 10.1016/j.jelechem.2019.113400
ER  - 
@article{
author = "Đurđić, Slađana and Vukojević, Vesna and Vlahović, Filip and Ognjanović, Miloš and Švorc, jubomir and Kalcher, Kurt and Mutić, Jelena and Stanković, Dalibor",
year = "2019",
publisher = "Elsevier",
journal = "Journal of Electroanalytical Chemistry",
title = "Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing",
volume = "850",
doi = "10.1016/j.jelechem.2019.113400"
}
Đurđić, S., Vukojević, V., Vlahović, F., Ognjanović, M., Švorc, j., Kalcher, K., Mutić, J.,& Stanković, D.. (2019). Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing. in Journal of Electroanalytical Chemistry
Elsevier., 850.
https://doi.org/10.1016/j.jelechem.2019.113400
Đurđić S, Vukojević V, Vlahović F, Ognjanović M, Švorc J, Kalcher K, Mutić J, Stanković D. Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing. in Journal of Electroanalytical Chemistry. 2019;850.
doi:10.1016/j.jelechem.2019.113400 .
Đurđić, Slađana, Vukojević, Vesna, Vlahović, Filip, Ognjanović, Miloš, Švorc, jubomir, Kalcher, Kurt, Mutić, Jelena, Stanković, Dalibor, "Application of bismuth (III) oxide decorated graphene nanoribbons for enzymatic glucose biosensing" in Journal of Electroanalytical Chemistry, 850 (2019),
https://doi.org/10.1016/j.jelechem.2019.113400 . .
29
16
29

Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita

Stanković, Dalibor; Samphao, Anchalee; Dojčinović, Biljana; Kalcher, Kurt

(Slovensko Kemijsko Drustvo, Ljubljana, 2016)

TY  - JOUR
AU  - Stanković, Dalibor
AU  - Samphao, Anchalee
AU  - Dojčinović, Biljana
AU  - Kalcher, Kurt
PY  - 2016
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/1997
AB  - This work presents the electrochemical behavior of levodopa (L-DOPA), at boron-doped diamond (BDD) electrodes, using cycling voltammetry (CV), in Britton-Robinson (BR) buffer solution, and application of the proposed electrode for the determination of L-DOPA in extracts from the seeds of velvet bean (Mucuna prurita Hook or Mucuna pruriens (L.) DC.). L-DOPA provides a well-defined and single oval-shape oxidation peak at +0.8 V vs. Ag/AgCl (3 M KCl) reference electrode in BR buffer solution at pH 3.0. Experimental parameters, such as pH of supporting electrolyte and square wave voltammetry (SWV) operating parameters (frequency and modulation amplitude) were optimized. The effect of possible interferences was evaluated. Under optimal conditions the detection limit of the developed method was 0.8 mu M and the calibration curve for L-DOPA was linear in the range from 2 to 100 mu M. The proposed method was successfully applied to the determination of L-DOPA in an extract from the seeds of Mucuna prurita. The obtained result was in good agreement with obtained by photometry with 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid (ABTS). The developed approach can be beneficial for the quantification of L-DOPA using a BDD electrode as up-to-date potential alternative sensor for electroanalytical applications.
PB  - Slovensko Kemijsko Drustvo, Ljubljana
T2  - Acta Chimica Slovenica
T1  - Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita
VL  - 63
IS  - 2
SP  - 220
EP  - 226
DO  - 10.17344/acsi.2015.1541
ER  - 
@article{
author = "Stanković, Dalibor and Samphao, Anchalee and Dojčinović, Biljana and Kalcher, Kurt",
year = "2016",
abstract = "This work presents the electrochemical behavior of levodopa (L-DOPA), at boron-doped diamond (BDD) electrodes, using cycling voltammetry (CV), in Britton-Robinson (BR) buffer solution, and application of the proposed electrode for the determination of L-DOPA in extracts from the seeds of velvet bean (Mucuna prurita Hook or Mucuna pruriens (L.) DC.). L-DOPA provides a well-defined and single oval-shape oxidation peak at +0.8 V vs. Ag/AgCl (3 M KCl) reference electrode in BR buffer solution at pH 3.0. Experimental parameters, such as pH of supporting electrolyte and square wave voltammetry (SWV) operating parameters (frequency and modulation amplitude) were optimized. The effect of possible interferences was evaluated. Under optimal conditions the detection limit of the developed method was 0.8 mu M and the calibration curve for L-DOPA was linear in the range from 2 to 100 mu M. The proposed method was successfully applied to the determination of L-DOPA in an extract from the seeds of Mucuna prurita. The obtained result was in good agreement with obtained by photometry with 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid (ABTS). The developed approach can be beneficial for the quantification of L-DOPA using a BDD electrode as up-to-date potential alternative sensor for electroanalytical applications.",
publisher = "Slovensko Kemijsko Drustvo, Ljubljana",
journal = "Acta Chimica Slovenica",
title = "Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita",
volume = "63",
number = "2",
pages = "220-226",
doi = "10.17344/acsi.2015.1541"
}
Stanković, D., Samphao, A., Dojčinović, B.,& Kalcher, K.. (2016). Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita. in Acta Chimica Slovenica
Slovensko Kemijsko Drustvo, Ljubljana., 63(2), 220-226.
https://doi.org/10.17344/acsi.2015.1541
Stanković D, Samphao A, Dojčinović B, Kalcher K. Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita. in Acta Chimica Slovenica. 2016;63(2):220-226.
doi:10.17344/acsi.2015.1541 .
Stanković, Dalibor, Samphao, Anchalee, Dojčinović, Biljana, Kalcher, Kurt, "Rapid Electrochemical Method for the Determination of L-DOPA in Extract From the Seeds of Mucuna Prurita" in Acta Chimica Slovenica, 63, no. 2 (2016):220-226,
https://doi.org/10.17344/acsi.2015.1541 . .
1
11
8
11