Fabian, Martin

Link to this page

Authority KeyName Variants
d0ba7bf3-118c-4aa6-88d8-6249db161dcc
  • Fabian, Martin (1)
Projects

Author's Bibliography

A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone

Ognjanović, Miloš; Stanković, Dalibor; Fabian, Martin; Vukadinovic, Aleksandar; Prijovic, Zeljko; Dojčinović, Biljana; Antić, Bratislav

(Wiley-Blackwell, Malden, 2018)

TY  - JOUR
AU  - Ognjanović, Miloš
AU  - Stanković, Dalibor
AU  - Fabian, Martin
AU  - Vukadinovic, Aleksandar
AU  - Prijovic, Zeljko
AU  - Dojčinović, Biljana
AU  - Antić, Bratislav
PY  - 2018
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/2354
AB  - In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe"RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are  LT = 0.31 mu M. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses.
PB  - Wiley-Blackwell, Malden
T2  - Electroanalysis
T1  - A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone
VL  - 30
IS  - 11
SP  - 2620
EP  - 2627
DO  - 10.1002/elan.201800357
ER  - 
@article{
author = "Ognjanović, Miloš and Stanković, Dalibor and Fabian, Martin and Vukadinovic, Aleksandar and Prijovic, Zeljko and Dojčinović, Biljana and Antić, Bratislav",
year = "2018",
abstract = "In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe"RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are  LT = 0.31 mu M. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses.",
publisher = "Wiley-Blackwell, Malden",
journal = "Electroanalysis",
title = "A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone",
volume = "30",
number = "11",
pages = "2620-2627",
doi = "10.1002/elan.201800357"
}
Ognjanović, M., Stanković, D., Fabian, M., Vukadinovic, A., Prijovic, Z., Dojčinović, B.,& Antić, B.. (2018). A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone. in Electroanalysis
Wiley-Blackwell, Malden., 30(11), 2620-2627.
https://doi.org/10.1002/elan.201800357
Ognjanović M, Stanković D, Fabian M, Vukadinovic A, Prijovic Z, Dojčinović B, Antić B. A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone. in Electroanalysis. 2018;30(11):2620-2627.
doi:10.1002/elan.201800357 .
Ognjanović, Miloš, Stanković, Dalibor, Fabian, Martin, Vukadinovic, Aleksandar, Prijovic, Zeljko, Dojčinović, Biljana, Antić, Bratislav, "A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone" in Electroanalysis, 30, no. 11 (2018):2620-2627,
https://doi.org/10.1002/elan.201800357 . .
21
12
20