Ranković, Petar M.

Link to this page

Authority KeyName Variants
7919e4eb-396b-40d4-8a60-51e07e37f1e4
  • Ranković, Petar M. (1)
Projects

Author's Bibliography

The effect of the filter type on the quality of “shake flask” solubility determinations

Marković, Olivera; Stojkov, Dragana D.; Ranković, Petar M.; Pešić, Miloš P.; Cvijetić, Ilija; Verbić, Tatjana

(Serbian Chemical Society, Belgrade / Srpsko hemijsko društvo, Beograd, 2016)

TY  - CONF
AU  - Marković, Olivera
AU  - Stojkov, Dragana D.
AU  - Ranković, Petar M.
AU  - Pešić, Miloš P.
AU  - Cvijetić, Ilija
AU  - Verbić, Tatjana
PY  - 2016
UR  - https://cer.ihtm.bg.ac.rs/handle/123456789/3400
AB  - The aim of the present study was to examine the influence of the filter type during phase
separation on solubility determination. Polyether sulfone (hydrophobic) and polyvinylidene fluoride (hydrophilic) filters were chosen. The concentration was measured by UV/Vis spectrophotometry. Carvedilol (base) and ibuprofen (acid) are used as a model compounds. LogP values were determined by miniaturized shake-flask method and by optimized potentiometric titration. It is shown that solubility data can be influenced by membrane filter type which is used for filtration, after the equilibrium is established during dissolution. Magnitude of this influence depends of lipophilicity and pKa value of molecule and a solution pH value.
AB  - Cilj ovog rada je ispitivanje uticaja vrste membrane filtera u procesu odvajanja faza pri određivanju rastvorljivosti „shake-flask“ metodom. Izabrani su polietar-sulfon (hidrofobni) i poliviniliden-fluorid (hidrofilni) filteri. Koncentracija je merena pomoću UV/Vis spektrofotometrije. Kao model supstance korišćeni su karvedilol (baza) i ibuprofen (kiselina). Minijaturizovanom „shake-flask“ metodom i optimizovanom metodom potenciometrijske titracije određene su i logP vrednosti. Pokazano je da rezultat određivanja rastvorljivosti može zavisiti od vrste membrane filtera koji se koristi za odvajanje filtrata nakon uspostavljanja ravnoteže u rastvoru tokom rastvaranja. Jačina uticaja zavisi od lipofilnosti i pKa vrednosti ispitavanog molekula kao i od pH vrednosti rastvora u kom se izvodi određivanje.
PB  - Serbian Chemical Society, Belgrade / Srpsko hemijsko društvo, Beograd
C3  - 53rd Meeting of the Serbian Chemical Society - Book of abstracts / 53. Savetovanje Srpskog hemijskog društva - Kratki izvodi radova, Kragujevac, 10-11.06.2016
T1  - The effect of the filter type on the quality of “shake flask” solubility determinations
T1  - Uticaj vrste filtera na kvalitet određivanja rastvorljivosti “shake-flask” metodom
SP  - 17
EP  - 17
UR  - https://hdl.handle.net/21.15107/rcub_cer_3400
ER  - 
@conference{
author = "Marković, Olivera and Stojkov, Dragana D. and Ranković, Petar M. and Pešić, Miloš P. and Cvijetić, Ilija and Verbić, Tatjana",
year = "2016",
abstract = "The aim of the present study was to examine the influence of the filter type during phase
separation on solubility determination. Polyether sulfone (hydrophobic) and polyvinylidene fluoride (hydrophilic) filters were chosen. The concentration was measured by UV/Vis spectrophotometry. Carvedilol (base) and ibuprofen (acid) are used as a model compounds. LogP values were determined by miniaturized shake-flask method and by optimized potentiometric titration. It is shown that solubility data can be influenced by membrane filter type which is used for filtration, after the equilibrium is established during dissolution. Magnitude of this influence depends of lipophilicity and pKa value of molecule and a solution pH value., Cilj ovog rada je ispitivanje uticaja vrste membrane filtera u procesu odvajanja faza pri određivanju rastvorljivosti „shake-flask“ metodom. Izabrani su polietar-sulfon (hidrofobni) i poliviniliden-fluorid (hidrofilni) filteri. Koncentracija je merena pomoću UV/Vis spektrofotometrije. Kao model supstance korišćeni su karvedilol (baza) i ibuprofen (kiselina). Minijaturizovanom „shake-flask“ metodom i optimizovanom metodom potenciometrijske titracije određene su i logP vrednosti. Pokazano je da rezultat određivanja rastvorljivosti može zavisiti od vrste membrane filtera koji se koristi za odvajanje filtrata nakon uspostavljanja ravnoteže u rastvoru tokom rastvaranja. Jačina uticaja zavisi od lipofilnosti i pKa vrednosti ispitavanog molekula kao i od pH vrednosti rastvora u kom se izvodi određivanje.",
publisher = "Serbian Chemical Society, Belgrade / Srpsko hemijsko društvo, Beograd",
journal = "53rd Meeting of the Serbian Chemical Society - Book of abstracts / 53. Savetovanje Srpskog hemijskog društva - Kratki izvodi radova, Kragujevac, 10-11.06.2016",
title = "The effect of the filter type on the quality of “shake flask” solubility determinations, Uticaj vrste filtera na kvalitet određivanja rastvorljivosti “shake-flask” metodom",
pages = "17-17",
url = "https://hdl.handle.net/21.15107/rcub_cer_3400"
}
Marković, O., Stojkov, D. D., Ranković, P. M., Pešić, M. P., Cvijetić, I.,& Verbić, T.. (2016). The effect of the filter type on the quality of “shake flask” solubility determinations. in 53rd Meeting of the Serbian Chemical Society - Book of abstracts / 53. Savetovanje Srpskog hemijskog društva - Kratki izvodi radova, Kragujevac, 10-11.06.2016
Serbian Chemical Society, Belgrade / Srpsko hemijsko društvo, Beograd., 17-17.
https://hdl.handle.net/21.15107/rcub_cer_3400
Marković O, Stojkov DD, Ranković PM, Pešić MP, Cvijetić I, Verbić T. The effect of the filter type on the quality of “shake flask” solubility determinations. in 53rd Meeting of the Serbian Chemical Society - Book of abstracts / 53. Savetovanje Srpskog hemijskog društva - Kratki izvodi radova, Kragujevac, 10-11.06.2016. 2016;:17-17.
https://hdl.handle.net/21.15107/rcub_cer_3400 .
Marković, Olivera, Stojkov, Dragana D., Ranković, Petar M., Pešić, Miloš P., Cvijetić, Ilija, Verbić, Tatjana, "The effect of the filter type on the quality of “shake flask” solubility determinations" in 53rd Meeting of the Serbian Chemical Society - Book of abstracts / 53. Savetovanje Srpskog hemijskog društva - Kratki izvodi radova, Kragujevac, 10-11.06.2016 (2016):17-17,
https://hdl.handle.net/21.15107/rcub_cer_3400 .