The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment
2011
Autori
Marković, RadmilaJugović, Branimir
Gvozdenović, Milica M.
Stevanović, Jasmina
Stevanović, Z.
Bugarin, Mile
Ostala autorstva
Markoš, JozefKonferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
This paper addresses on investigation the possibility of electrolytic treatment the sulphur acidic waste solution, obtained in the conventional electrolytic copper refining process. The copper anodes with non-standard nickel, lead, tin and antimony content were specially prepared for the refining process. Nickel content of all anodes was approximately 7.5 mass %, and the content of lead, tin and antimony was varied. Results, obtained using the standard electrochemical techniques, have indicated that the anodes could be used under the same conditions as well as in the conventional copper refining process.
Ključne reči:
copper anodes / non-standard chemical composition / electrorefining / sulphur acidic waste solution / alloying elementsIzvor:
Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering, 2011, 968-971Izdavač:
- Tatranské Matliare : Slovak Society of Chemical Engineering
Finansiranje / projekti:
Institucija/grupa
IHTMTY - CONF AU - Marković, Radmila AU - Jugović, Branimir AU - Gvozdenović, Milica M. AU - Stevanović, Jasmina AU - Stevanović, Z. AU - Bugarin, Mile PY - 2011 UR - http://dais.sanu.ac.rs/123456789/550 UR - https://cer.ihtm.bg.ac.rs/handle/123456789/2618 AB - This paper addresses on investigation the possibility of electrolytic treatment the sulphur acidic waste solution, obtained in the conventional electrolytic copper refining process. The copper anodes with non-standard nickel, lead, tin and antimony content were specially prepared for the refining process. Nickel content of all anodes was approximately 7.5 mass %, and the content of lead, tin and antimony was varied. Results, obtained using the standard electrochemical techniques, have indicated that the anodes could be used under the same conditions as well as in the conventional copper refining process. PB - Tatranské Matliare : Slovak Society of Chemical Engineering C3 - Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering T1 - The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment SP - 968 EP - 971 UR - https://hdl.handle.net/21.15107/rcub_dais_550 ER -
@conference{ author = "Marković, Radmila and Jugović, Branimir and Gvozdenović, Milica M. and Stevanović, Jasmina and Stevanović, Z. and Bugarin, Mile", year = "2011", abstract = "This paper addresses on investigation the possibility of electrolytic treatment the sulphur acidic waste solution, obtained in the conventional electrolytic copper refining process. The copper anodes with non-standard nickel, lead, tin and antimony content were specially prepared for the refining process. Nickel content of all anodes was approximately 7.5 mass %, and the content of lead, tin and antimony was varied. Results, obtained using the standard electrochemical techniques, have indicated that the anodes could be used under the same conditions as well as in the conventional copper refining process.", publisher = "Tatranské Matliare : Slovak Society of Chemical Engineering", journal = "Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering", title = "The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment", pages = "968-971", url = "https://hdl.handle.net/21.15107/rcub_dais_550" }
Marković, R., Jugović, B., Gvozdenović, M. M., Stevanović, J., Stevanović, Z.,& Bugarin, M.. (2011). The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering Tatranské Matliare : Slovak Society of Chemical Engineering., 968-971. https://hdl.handle.net/21.15107/rcub_dais_550
Marković R, Jugović B, Gvozdenović MM, Stevanović J, Stevanović Z, Bugarin M. The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering. 2011;:968-971. https://hdl.handle.net/21.15107/rcub_dais_550 .
Marković, Radmila, Jugović, Branimir, Gvozdenović, Milica M., Stevanović, Jasmina, Stevanović, Z., Bugarin, Mile, "The use of anodic linear sweep voltammetery analysis (ALSV) for characterization the copper anodes used for sulphur acidic waste solution treatment" in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering (2011):968-971, https://hdl.handle.net/21.15107/rcub_dais_550 .