Приказ основних података о документу

dc.creatorFaraj, Musbah Abduljalil M.
dc.creatorŠolević Knudsen, Tatjana
dc.creatorStojanović, Ksenija
dc.creatorPavlovic, Sonja Ivkovic
dc.creatorNytoft, Hans Peter
dc.creatorJovančićević, Branimir
dc.date.accessioned2019-01-30T17:53:26Z
dc.date.available2019-01-30T17:53:26Z
dc.date.issued2017
dc.identifier.issn0352-5139
dc.identifier.urihttps://cer.ihtm.bg.ac.rs/handle/123456789/2098
dc.description.abstractThe values of parameters calculated from distribution and abundance of the selected pentacyclic terpanes in crude oils from Libya and Serbia, which were originally derived from gas chromatography-mass spectrometry (GC-MS) were compared with results of quantification based on gas chromatography-mass spectrometry-mass spectrometry (GC-MS-MS). The parameters analyzed are the most often used terpane source and maturity parameters, which were applied to a large sample set of 70 oils, originating from five oil fields. The aim of the paper was to investigate to which extent the measurements of the selected parameters by these two instrumental techniques agree and to determine the influence of differences between parameter values on geochemical interpretation. For that purpose two methods, concordance correlation coefficient and mean-difference plot were used. The obtained results indicate that calculation of C(27)18 alpha(H)-22,29,30-trisnorneohopane/(C(27)18 alpha(H)-22,29,30-trisnorneohopane +C(27)17 alpha(H)-22,29,30-trisnorhopane), C(29)18 alpha(H)-30-norneohopane/C(29)17 alpha(H) 21 beta(H)-30-norhopane and C(29)17 alpha(H)21 beta(H)-30-norhopane/ C(30)17 alpha(H)21 beta(H)-hopane ratios either by GC-MS or GC-MS-MS do not significantly influence interpretation. On the other hand, the determination of C(30)17 beta(H)21 alpha(H)-moretane/C(30)17 alpha(H)21 beta(H)-hopane ratio, gammacerane index and oleanane index by GC-MS vs. GC-MS-MS could notably affect interpretation. These differences can be explained by the co-elution and the peak overlapping in GC-MS but also by better separation, higher precision and better selectivity of the GC-MS-MS. Deviation of the almost all studied parameters from the line of equality was similar for the oils from the same oil field but some differences were observed for the oils from different oil fields. Therefore, when GC-MS-MS results are to be used in organic geochemical interpretations, a regional calibration of GC-MS vs. GC-MS-MS relationship for each petroleum system is highly recommended.en
dc.publisherSerbian Chemical Soc, Belgrade
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/176006/RS//
dc.relationOrganisation for the Prohibition of Chemical Weapons (OPCW)
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceJournal of the Serbian Chemical Society
dc.subjectoilsen
dc.subjectterpanesen
dc.subjectGC-MSen
dc.subjectGC-MS-MSen
dc.subjectconcordance correlation coefficienten
dc.subjectmean-difference ploten
dc.titleGC-MS vs. GC-MS-MS analysis of pentacyclic terpanes in crude oils from Libya and Serbia - A comparison of two methodsen
dc.typearticle
dc.rights.licenseBY-NC-ND
dcterms.abstractФарај, Мусбах Aбдуљалил М.; Стојановиц, Ксенија; Нyтофт, Ханс Петер; Јованцицевиц, Бранимир; Шолевић Кнудсен, Татјана; Павловиц, Соња Ивковиц;
dc.citation.volume82
dc.citation.issue11
dc.citation.spage1315
dc.citation.epage1331
dc.citation.other82(11): 1315-1331
dc.citation.rankM23
dc.identifier.doi10.2298/JSC170419075A
dc.identifier.fulltexthttps://cer.ihtm.bg.ac.rs//bitstream/id/8528/2096.pdf
dc.identifier.scopus2-s2.0-85037610284
dc.identifier.wos000417845500009
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу